Technalogix Ltd
Adrenaline Control System
VI-71
Ensure that your receiver’s port is set to 162
The system will generate a general trap on any error flag and send an 8bit value indicating the
type of error.
Bit 0(LSB)
Overdrive
Bit 1
High VSWR
Bit 2
High Temperature
Bit 3
High Speed Hardware Shutdown
Bit 4(MSB)
High Input Level