Page 5
3.2 Technical features
T
ec
hn
ic
a
l fe
atu
res
Supply voltage
8
÷ 28 VDC
Current demand
Typical
70 mA
Maximal
120 mA
Keypad layout
Numeric keypad, 12 keys
ID technology,
typical reading range
EM Marin
5 cm (with ISO card)
Real-time clock
Yes, with 24 hrs. back-up
Memory
Cards
2,000 ID, 2 programming cards
Events
3,400
Time schedules
64
Inputs
1
st
input
Logical potential-free contact
2
nd
input
Logical potential-free contact
Outputs
Door lock
Relay NC/NO, 2A/24V
Alarm
Relay NC/NO, 2A/24V
I/O Port
External device
Ext. tamper / ext. reader buzzer control /
input for IDS status monitoring / module
disable function / reading synchronization
MASTER/SLAVE modes
Indicators
3x LED
1x PIEZO
Tamper protection
Opening the cover
Against tearing-off
Opto-electronic
Communication interface
RS 485
Alternative data input/output
WIEGAND (configurable)
Table 2: Technical features
3.3 Special accessories
A
c
c
es
s
orie
s
WIO 22
51901200
Remote control module, 2x relay
Table 3: Special accessories
3.4 Using WIO 22 module for remote output control
The
WIO 22
remote control
WIEGAND
relay module is designated for secure output control
of APS system reader modules. The door open or other functions can be controlled from the
module located inside the secure area, while the reader module can be located in the non-
secure area.
The module is controlled by
WIEGAND
signal directly from the reader module working in
standard operating mode. The module must be paired with appropriate reader module before
use.
The
WIO 22
module is always required when the reader module is used for
IDS control
.