background image

 

Page 14 

W

ieg

a

nd

 

ID media technology 

Available configuration of the WIEGAND output format 

EM Marin 

26bit, 32bit, 42bit, 44bit 

Table 11: ID media format in WIEGAND operating mode 

Two long beeps and the red LED lit feature powering up the module. The green LED blink 
indicates an ID reading. 

Individual signals function in 

WIEGAND output

 operating mode is described in 

table 12

W

ieg

a

nd

 

Input 1  

Beeper control (0 V active) 

Input 2  

Yellow LED control (0 V active) 

Output 1 (relay) 

Tamper signaling; it follows the alarm state of tamper sensors 
(tamper signal = relay switched on)

 3)

 

Table 12: Signal function in WIEGAND operating mode 

Key codes sent in 

WIEGAND output

 operating mode are described in 

table 13

K

ey

 c

od

es

  

Key pressed 

Keypad configuration 

PIN / ID keypad 

Key code keypad 

 9 (digits) 

Codes 1 

 9 

# (hash) 

Code 11 

Code 0 

Code 10 

 (star) 

Code 10 

Code 0 

Table 13: Key codes sent in WIEGAND output operating mode 

Since the 

FW version 5.09

 the reading synchronization of a 

couple of TECHFASS readers 

is 

implemented, enabling to 

cancel the mutual disturbance

 of the modules. The reader module 

offers the 

Wiegand data interface

 

synchronization

 in 

MASTER

 mode. 

6.7  Keypad function 

The keypad function setting can be set to one of the following options: 

 

Key code 

– this option is used when the keypad is used for entering a code of reason 

to exit. 

 

PIN

 

– with this option selected the keypad is used for entering PIN codes, a correct PIN 

is required for valid identification when this option is selected 

If the “

Suppress PIN request according to a time schedule

” function is set, the PIN code 

entering is not requested when the used time schedule is valid. 

 

ID

 

– this option enables entering a code at the keypad which is used as a user’s read 

ID medium; the time for locking up the keypad when an unknown ID is entered 5 times 
in a row can be set there as well, the setting range is from 0 to 2550s with a 10s step. 

Table  14

  defines  the  interpretation  of  keys  pressed  at  the  keypad  of 

MREP  78  reader 

modules

 according to the program configuration of the keypad function. 

Содержание APS mini MREP 78 Series

Страница 1: ...ll mounting for BPT Xolid panels nad for OEM use in own applications User s guide 2004 2019 TECH FASS s r o V t nsk 1611 19 153 00 Prague Czech Republic www techfass cz techfass techfass cz Date of re...

Страница 2: ...eters of the reader module 9 5 1 Configurable parameters 9 5 2 Reader module parameters setting 9 6 Reader module functioning 10 6 1 Door Open function description 10 6 2 Function permanent door lock...

Страница 3: ...e used for a simple IDS control 2 1 MREP 78 module The reader module pic 1a is intended for wall mounting in both indoor and outdoor environment 2 2 MREP 78X module The reader module pic 1b is designe...

Страница 4: ...odule features 2 TF EM MREP 78 TF Wall mounted 53478400 MREP 78X TF Xolid panel 53478410 MREP 78E TF OEM solution 53478420 MREP 78 EM Wall mounted 53478401 MREP 78X EM Xolid panel 53478411 MREP 78E EM...

Страница 5: ...r protection Opening the cover Against tearing off Opto electronic Communication interface RS 485 Alternative data input output WIEGAND configurable Table 2 Technical features 3 3 Special accessories...

Страница 6: ...pply 2 Blue 0 V pow supply 3 Yellow Input 1 4 Grey brown 0 V 5 Grey Input 2 6 Black A RS 485 7 White B RS 485 8 Violet NO lock relay 9 Grey pink NC lock relay 10 Brown C lock relay Table 5 Terminal de...

Страница 7: ...inuously lit GREEN Indicating IDS disarmed status Continuously lit RED Indicating IDS armed status Continuously lit YELLOW Indicating IDS arming disarming status Table 8 LED indicators description 4 3...

Страница 8: ...plies generate enough noise to cause reader malfunction it is recommended to use linear system power supplies Radiated noise is transmitted through the air It can be caused by computer monitors or oth...

Страница 9: ...30 s Acoustic signalization time Forced door 0 255 s 30 s Acoustic signalization time Door ajar 0 255 s 0 s Acoustic signalization time APB alarm 0 255 s 0 s Signalization time Card alarm 0 255 s 30 s...

Страница 10: ...ase time has elapsed see configuration table In case the toggle function of the door lock relay is set the door lock relay status is switched and the beeper is activated when not disabled when the Doo...

Страница 11: ...es with setting of the signaling timer 0 occurs the alarm output is activated It can control any alarm device directly or it can be processed further After terminating all alarm conditions the alarm o...

Страница 12: ...ID media format can be changed into selected 24 32 or 40 bits length of ID code The default length is 40 bits This setting is only used when unifying of the ID media codes length is required in combi...

Страница 13: ...he interpretation of its status is I O Port active status 0V signal from the IDS at the I O Port IDS armed The IDS can be controlled with one of the following modes Status control the IDS is controlle...

Страница 14: ...09 the reading synchronization of a couple of TECHFASS readers is implemented enabling to cancel the mutual disturbance of the modules The reader module offers the Wiegand data interface synchronizati...

Страница 15: ...ogramming mode by reading one of the two programming cards cards and The programming mode cannot be entered while the module is in hardware address setting mode for modules with HW address setting via...

Страница 16: ...st card code the reader module goes back into standard operating mode Pic 4 a Inserting cards codes 6 8 2 Deleting cards codes from the reader s memory For deleting the cards from the reader module s...

Страница 17: ...ated by slow flashing of yellow LED Read the programming card for inserting 5 times in a row or enter the programming code the reader will go into Deleting cards above or below mode indicated by fast...

Страница 18: ...reader module memory All operations adding and deleting cards should be stored in the table Following example shows correct usage of the programming cards and proper filing of the actions Inserting 5...

Страница 19: ...ange a PIN code in the reader s memory by pressing the key sequence Esc 1 Enter at a reader in a mode with a keypad for PIN entering The reader enters PIN changing mode In this mode the user attemptin...

Страница 20: ...ant input is disconnected 6 11 1 Time Antipassback The Time Antipassback is defined by the ABP timer initial value in minutes which is set to the ID after passing at the reader module If the users use...

Страница 21: ...the third input output port The logic of the function is individually configurable The function is active whenever one or both of the configured inputs are active The module behavior is as described...

Страница 22: ...evaluation can be seen on Pic 5 Pic 5 Simplified access rights evaluation VALID INVALID PIN UNKNOWN ID FOUND ACCESS DRIVEN BY TIME SCHED ACCESS ALWAYS GRANTED HOLIDAY ACCESS GRANTED FOR HOLIDAY AND A...

Страница 23: ...the indication is based only on the control relay status in the impulse control mode it is given by the I O Port status The meaning of the LED color and the logic of IDS signal at the I O Port are des...

Страница 24: ...LED indicator turns yellow the reader starts to indicate disarming process with short beeping and awaits the IDS to change its status signal at the I O Port If the status is changed the LED indicator...

Отзывы: