Page 19
6.11
Disabling function
This function is implemented since the
FW version 5.08
.
The
module disabling function
can be set at the second. The logic of the function is
configurable.
The module behavior is as described below when the disabling function is active:
•
User with access driven by a time schedule cannot run the door open function
•
User with access always granted is not affected by the disabling function
•
Remote door open function cannot be performed
•
Remote identification with ID is disabled for users with access driven by a time schedule
The disabling status changes and disabled actions are logged in the events archive.
6.12
Reading synchronization
Since the
FW version 5.09
the reading synchronization of a
couple of TECHFASS readers
is
implemented, enabling to
cancel the mutual disturbance
of the modules. The reader module
offers to use the
IO synchronization
in
MASTER
mode. The
output 3
is used as the
synchronization signal
.