Page 10
5.2 Factory defaults
Default factory parameters of TCP/IP interface are:
•
IP address:
192.168.1.253
•
IP port:
10001
•
Password:
1234
•
Subnet mask:
255.255.255.0
*)
•
Gateway IP address:
192.168.1.1
*)
*)
These settings are available only when configuring the device via telnet terminal.
These parameters can be set by pressing the
RESET
(
tab. 10
) button for
5 seconds period
or more. The exceeding of this period is signalized with a fast flashing of a LED. A shorter
depression of the
RESET
button restarts the terminal and keeps its settings.
5.3 Configuring terminal from the configuration screen
To enter the
configuration
screen
touch the terminal screen
in
area 12
(see
pic. 4
) 5 times in a row. A
login dialog
will
appear (
pic. 5
). Use the arrows to enter the password (for
next character touch the empty space just next to the first
character) and then press the
OK
button.
After entering the configuration screen you can change
terminal communication, screen and security settings (
pic.
6a, b, c
).
5.3.1 Communication screen
3)
3)
TCP/IP settings are meaningful in
IP
versions of
MDEM 31
only.
At this tab of the configuration screen you can change the
IP address
,
IP port
and the
HW
address of the terminal. Use arrows to set desired values. After setting up all parameters,
use the
OK
button to save the settings or the
Cancel
button to cancel all changes.
5.3.2 Device screen
At this tab of the configuration screen you can change
brightness
and
contrast
of the display.
Use arrows to set desired intensity. After setting up all parameters, use the
OK
button to
save the settings or the
Cancel
button to cancel all changes.
Pic. 5: Configuration screen login
Pic. 6a, b, c: Communication, device and security settings from the configuration screen