background image

9.           Dimensions 

                                                                   TECFLUID, S.A. 
                                                                   Narcís Monturiol, 33 
                                                                   E-08960  Sant Just Desvern 
                                                                   Tel. + 34 933 724 511 - Fax + 34 934 734 449 
                                                                   E-mail: [email protected] 
                                                                   Internet: www.tecfluid.com 
 

The technical data in this pamphlet is subject to modification without notification, if the technical innovations in the product or 
manufacturing processes so require. 

WARRANTY

 

Tecfluid S.A. GUARANTEES ALL ITS PRODUCTS FOR A PERIOD OF 24 MONTHS, after 
consignment, against all defects in materials and workmanship. 
This warranty does not cover failures which can be imputed to misuse, use in an application different 
to that specified in the order, the result of service or modification by un-authorized persons, bad 
handling or accident. 
This warranty is limited to cover the repair or replacement defective parts which have not been 
damaged by misuse. 
This warranty is limited to the repair of the equipment and all further and eventually following 
damages are not covered by this warranty. 
Any consignment of equipment to our factory or distributor must be previously authorised. The 
consignment should be done with the equipment well packed, clean of any liquids, grease or 
hazardous materials. Tecfluid S.A. will not accept any responsibility for damage done during 
transport.  
Together with the equipment, a note should be enclosed indicating the failure observed, the name, 
address and telephone number of the sender.  

Содержание CP420R

Страница 1: ...Programmable flow rate transmitter CP420R CH420R Instructions Manual R MI CH420R Rev 0 English version...

Страница 2: ...There are three push buttons with the following functions 2 1 Programming In all the programming screens the RESET push button exits the screen without saving the data in the memory even if changes in...

Страница 3: ...rogramming In the first screen we program the flow rate equivalent to 4 mA lower range The measuring units will be the ones chosen in the previous screen The push buttons have the same function as the...

Страница 4: ...in the instrument Example 1 Shortage of volume If we have a flow meter body which specifies i l 1 985 and when we check the volume of a batch we find that instead of having 100 litres as programmed we...

Страница 5: ...er of Device Variables 2 Number of Dynamic Variables 1 Mappable Dynamic Variables No Number of Common Practice Commands 13 Number of Device Specific Commands 2 Bits of Additional Device Status 12 Alte...

Страница 6: ...digits 7 Size of the digit 8 mm Reset By means of push button 8 3 Flow rate Indication N of digits 5 Size of the digit 5 mm 8 4 General characteristics Ingress protection IP40 Ambient temperature rang...

Страница 7: ...imum input frequency is 0 06 Hz 8 6 2 Turbine If the Pulse input is configured for Turbine jumpers in position 1 2 a coil of a magnetic pick up can be connected between terminals 1 2 The input impedan...

Страница 8: ...specified in the order the result of service or modification by un authorized persons bad handling or accident This warranty is limited to cover the repair or replacement defective parts which have no...

Отзывы: