2.3. Reset 

By pushing the RESET push button, the counter will be set to zero and it will continue to 
count. 

3.

MAINTENANCE 

It doesn’t require any special maintenance. 

4.

MEASUREMENT ERROR CORRECTIONS 

The calibration of the mechanical flow meters is made with water at 20 

o

C to obtain a 

calibration for a liquid of density 1 kg/l and viscosity of 1 mPa·s. If the flow meter is used with 
a liquid of other characteristics from the above specified or for reasons of turbulences in the 
flow, measurement errors can be induced. 
To correct these types of errors we can modify the pulses per litre factor programmed in the 
instrument. 
 

Example 1 - Shortage of volume 

 
If we have a flow meter  body which specifies  i/l = 1.985, and when we check the volume of a 
batch, we find that instead of having 100 litres as programmed, we only have 95 litres (5% 
less) and we must apply the following correction: 

 

i/l    = Original Pulses per litre Factor                   = 1.985 
V    = Expected Volume                                         = 100 
Vr   = Real Volume                                                 = 95 

i/l n = i/l

V

Vr

i/l n  = New Pulses per litre Factor                       = ? (2.089) 

 

Example 2 - Excess of volume 

 

If we have a flow meter  body which specifies  i/l = 1.985, and when we check the volume of a 
batch, we find that instead of having 100 litres as programmed, we only have 105 litres (5% 
more) and we must apply the following correction: 

 

 i/l    = Original Pulses per litre Factor                   = 1.985 
V    = Expected Volume                                         = 100 
Vr   = Real Volume                                                 = 105 

i/l n = i/l

V

Vr

i/l n  = New Pulses per litre Factor                       = ? (1.887)

 

Содержание CP420R

Страница 1: ...Programmable flow rate transmitter CP420R CH420R Instructions Manual R MI CH420R Rev 0 English version...

Страница 2: ...There are three push buttons with the following functions 2 1 Programming In all the programming screens the RESET push button exits the screen without saving the data in the memory even if changes in...

Страница 3: ...rogramming In the first screen we program the flow rate equivalent to 4 mA lower range The measuring units will be the ones chosen in the previous screen The push buttons have the same function as the...

Страница 4: ...in the instrument Example 1 Shortage of volume If we have a flow meter body which specifies i l 1 985 and when we check the volume of a batch we find that instead of having 100 litres as programmed we...

Страница 5: ...er of Device Variables 2 Number of Dynamic Variables 1 Mappable Dynamic Variables No Number of Common Practice Commands 13 Number of Device Specific Commands 2 Bits of Additional Device Status 12 Alte...

Страница 6: ...digits 7 Size of the digit 8 mm Reset By means of push button 8 3 Flow rate Indication N of digits 5 Size of the digit 5 mm 8 4 General characteristics Ingress protection IP40 Ambient temperature rang...

Страница 7: ...imum input frequency is 0 06 Hz 8 6 2 Turbine If the Pulse input is configured for Turbine jumpers in position 1 2 a coil of a magnetic pick up can be connected between terminals 1 2 The input impedan...

Страница 8: ...specified in the order the result of service or modification by un authorized persons bad handling or accident This warranty is limited to cover the repair or replacement defective parts which have no...

Отзывы: