background image

                                                                   TECFLUID, S.A. 
                                                                   Narcís Monturiol, 33 
                                                                   E-08960  Sant Just Desvern 
                                                                   Tel. + 34 933 724 511 - Fax + 34 934 734 449 
                                                                   E-mail: [email protected] 
                                                                   Internet: www.tecfluid.com 

The technical data in this pamphlet is subject to modification without notification, if the technical innovations in the product or 

manufacturing processes so require. 

WARRANTY

Tecfluid S.A. GUARANTEES ALL ITS PRODUCTS FOR A PERIOD OF 24 MONTHS, after 
consignment, against all defects in materials and workmanship. 

This warranty does not cover failures which can be imputed to misuse, use in an application different 
to that specified in the order, the result of service or modification by un-authorized persons, bad 
handling or accident. 

This warranty is limited to cover the repair or replacement defective parts which have not been 
damaged by misuse. 

This warranty is limited to the repair of the equipment and all further and eventually following 
damages are not covered by this warranty. 

Any consignment of equipment to our factory or distributor must be previously authorised. The 
consignment should be done with the equipment well packed, clean of any liquids, grease or 
hazardous materials. Tecfluid S.A. will not accept any responsibility for damage done during 
transport.  

Together with the equipment, a note should be enclosed indicating the failure observed, the name, 
address and telephone number of the sender.  

Содержание CI-420

Страница 1: ...t input 3 2 3 Analog output connection 4 2 4 Pulse output connection 4 3 SETTING UP 4 4 CONFIGURATION 5 5 TECHNICAL CHARACTERISTICS 6 5 1 Working conditions 6 5 2 Mains supply 6 5 3 Analog output 6 5...

Страница 2: ...voltage outputs to obtain the following voltage outputs Beginning of Scale Full Scale 0 V 5 V 0 V 10 V 1 V 5 V 2 V 10 V The value of fr the full scale frequency is selected by means of four BCD switc...

Страница 3: ...2 2 1 Pick up Input For the input from turbine type flowmeters which use magnetic inductive pick ups to detect the movement of the turbine blades the wiring must be made as following CI 420 Terminal...

Страница 4: ...ct the four significant digits and with the jumper we select the position of the decimal point To get to the switches a screwdriver can be used to lever out the top cover which is just clipped in its...

Страница 5: ...ent is configured for a COVOL input and 4 20 mA output The JP1 and JP2 jumpers are used to configure the type of input and should not be moved The jumpers JP3 JP4 JP5 JP6 are used to configure the typ...

Страница 6: ...e 5 3 Analog Output The analog output is configured internally for current or voltage output Current Output Maximum Load 600 ohms Voltage Output Minimum Load 10 000 ohms 5 4 Pulse inputs 1 The input c...

Страница 7: ...owing drawings the outside dimensions and the layout of the fastening holes for screws are given The layout of the fastening holes is given looking at the top of the instrument The weight of the instr...

Страница 8: ...ed in the order the result of service or modification by un authorized persons bad handling or accident This warranty is limited to cover the repair or replacement defective parts which have not been...

Отзывы: