 The shield is connected to one end of the reed switch and the live to the other end. 
A pulse generator with an open collector output (NPN transistor) can be connected to this 
input mode. In this case the emitter (or common) must be connected to terminal 14 and the 
collector to terminal 16. 

2.3 Analog Output Connection 

The analog output connected to terminals 9 and 10. Terminal 9 is the positive of the output and 
terminal 10 is the negative (common). 

When the instrument is used for a current output then the load applied to the output should be 
less than 600 ohms. 

When the instrument is used for a voltage output then the load applied to the output should be 
greater than 10,000 ohms. 

4

3. SETTING UP 

Once the instrument is installed the 
only thing that has to be done is 
setting the frequency which must de 
applied to the input frequency to 
obtain the full scale analog output. 

To introduce this frequency we have 
four BCD coded switches and a 
jumper with four positions. With the 
four BCD coded switches we select 
the four significant digits and with the 
jumper we select the position of the 
decimal point. To get to the switches, 
a screwdriver can be used to lever out 
the top cover, which is just clipped in 
its place. 

The jumper must be in one of the 
four positions provided. The 
instrument will not work correctly if 
the jumper is not in one of the four 
positions. 

2.4 Pulse output connection  

Terminal 12 is the emitter of an opto-
isolated NPN transistor and terminal 11 is 
the collector. 

This output can be used to activate 
electromagnetic units such as DC 
counters or relays. 

No protections for excess current or 
voltage spikes are provided. These 
should be installed externally as required.  

Example of connection to a PLC 

CI-420

PLC

12

+ 24 V

0 V

Input

Connection to a PLC with a "PNP" input

11

0

0

0

0

0

0

0

0

0

0

0

0

4

4

4

4

4

4

4

4

4

4

4

4

9

9

9

9

9

9

9

9

9

9

9

9

3

3

3

3

3

3

3

3

3

3

3

3

8

8

8

8

8

8

8

8

8

8

8

8

2

2

2

2

2

2

2

2

2

2

2

2

7

7

7

7

7

7

7

7

7

7

7

7

1

1

1

1

1

1

1

1

1

1

1

1

6

6

6

6

6

6

6

6

6

6

6

6

5

5

5

5

5

5

5

5

5

5

5

5

1

1

1

2

2

2

3

3

3

0

0

0

0

4

4

4

4

9

9

9

9

3

3

3

3

8

8

8

8

2

2

2

2

7

7

7

7

1

1

1

1

6

6

6

6

5

5

5

5

1 2 3 4

4

4

4

Frequency = 13,29  Hz

Frequency = 521,3  Hz

Frequency =1,234  Hz

Frequency = 1234  Hz

Содержание CI-420

Страница 1: ...t input 3 2 3 Analog output connection 4 2 4 Pulse output connection 4 3 SETTING UP 4 4 CONFIGURATION 5 5 TECHNICAL CHARACTERISTICS 6 5 1 Working conditions 6 5 2 Mains supply 6 5 3 Analog output 6 5...

Страница 2: ...voltage outputs to obtain the following voltage outputs Beginning of Scale Full Scale 0 V 5 V 0 V 10 V 1 V 5 V 2 V 10 V The value of fr the full scale frequency is selected by means of four BCD switc...

Страница 3: ...2 2 1 Pick up Input For the input from turbine type flowmeters which use magnetic inductive pick ups to detect the movement of the turbine blades the wiring must be made as following CI 420 Terminal...

Страница 4: ...ct the four significant digits and with the jumper we select the position of the decimal point To get to the switches a screwdriver can be used to lever out the top cover which is just clipped in its...

Страница 5: ...ent is configured for a COVOL input and 4 20 mA output The JP1 and JP2 jumpers are used to configure the type of input and should not be moved The jumpers JP3 JP4 JP5 JP6 are used to configure the typ...

Страница 6: ...e 5 3 Analog Output The analog output is configured internally for current or voltage output Current Output Maximum Load 600 ohms Voltage Output Minimum Load 10 000 ohms 5 4 Pulse inputs 1 The input c...

Страница 7: ...owing drawings the outside dimensions and the layout of the fastening holes for screws are given The layout of the fastening holes is given looking at the top of the instrument The weight of the instr...

Страница 8: ...ed in the order the result of service or modification by un authorized persons bad handling or accident This warranty is limited to cover the repair or replacement defective parts which have not been...

Отзывы: