1-42
Programming the sen-Touch electronics
The sen-Touch electronics can be programmed within
the first hour after connecting up to the power supply. In
the event of a power failure, the last settings saved are
retained. Each configurable function is assigned a position
on one of the two touch fields.
Large touch field:
Position
Function
1
Factory setting
2
Hygiene flush off
3
Hygiene flush 24 h
4
Hygiene flush 56 h
5
Hygiene flush 84 h
6
Hygiene flush 168 h
7
Hygiene flush 336 h
8
Hygiene flush 672 h
9
Illumination level 1 very bright
10
Illumination level 2 standard
11
Illumination level 3 dimmed
12
Illumination level 4 darker
13
Automatic flush off
14
Safety flush on
= factory setting
Small touch panel:
Position
Function
1
Identification very short-distance
2
Identification short-distance
3
Identification standard
4
Subsequent odour extraction 5 min
5
Subsequent odour extraction 2 min
6
Subsequent odour extraction 1 min
7
Subsequent odour extraction off
8
Fan setting, extra quiet
9
Fan setting, standard
10
Fan setting power
11
Cleaning function on
12
Cleaning function off
13
Activate illumination 20 sec*
14
Activate illumination 2 mins
15
Activate illumination 3 mins
16
Activate illumination 4 mins
17
Activate illumination 5 mins
18
Activate illumination permanently*
= factory setting
* function only for exhibitions
Procedure
This is how to program the sen-Touch electronics:
• Touch the large or small touch field with your hand.
Programming mode starts after 10 seconds with a quick
series of short beeps.
• After the start-up phase, a sequence of the same beeps
can be heard. Count these – with your hand on the
button – until you reach the required function.
• Now remove your hand; a long beep can be heard.
Example:
Setting the hygiene flush to 84 hours.
. . . .
Hand on
large touch field
Remove hand
Start 1 2 3 4 5
OK
Count the individual beeps until
the desired position is reached
Cleaning function
When the cleaning function is activated, the touch panel
is deactivated for 30 seconds (prerequisite: function 11 is
selected on the small touch field).
• Activating the cleaning function:
Touch both touch fields at the same time for 7 seconds.
Once this time has elapsed, the previously set functions
are automatically available again.
The cleaning function can only be activated in standard
mode and not during the programming phase.
Safety flush
When the automatic flush function is activated, an automat-
ic flush is carried out 2 minutes after the last time a person
was detected in the recognition range.
Only use this function in public toilets with cubicles!
Manual flush
It is possible to flush the toilet without power — e.g. fol-
lowing a power failure: To do so, remove the upper glass
facing from the wall and press the red actuation rod.
TECElux – Fine installation