1-20
Attaching individual modules to the floor
Unless screwed tightly to a section tube, the feet of the
TECElux modules should be attached to the bare floor
using the screws and dowels supplied. In the process,
the entire length of the dowels must be anchored in the
screed. The screed's compression strength must be at
least 5 N/mm
2
. If mounting on a wooden floor, reliable
fastening to the floor structure must be ensured.
Connecting the drain bend
A connection to the DN 90 or DN 100 connecting sleeve
can be created using the drain bend. It is possible to
create a welded connection with the DN 90 connection
trims of the flexible drain bend (only on modules with
“m-Lift” function, TECElux 200 and 400).
The flexible drain bend can be installed horizontally on
both sides, or vertically downwards.
Horizontal installation of the flexible drain bend (TECElux 200 and 400)
Vertical installation of the flexible drain bend (TECElux 200 and 400)
If installed horizontally, the fastening clip is directly
screwed onto the module frame. If installed vertically, the
clip must be screwed into the wall.
Flexible length extension
If the flexible drain bend is used, cleaning spirals should
not be inserted as they could damage the flexible element.
Panel facing and wall construction
The pre-wall is clad with conventional wet room boards
(e.g. TECEprofil panel plates 9200000), at least 18 mm or
2 x 12.5 mm.
The large bare-wall protection must also be mounted.
Attach the bare-wall protection to the module.