1-18
Installation in a floor-to-ceiling C-profile metal
stud wall
Installation in a floor-to-ceiling C-profile metal stud wall
In double-stud walls, the individual stud rows must be
tightly connected to each other in accordance with
DIN 18183. To achieve this, 30 cm long brackets are
screwed between the C-profiles. Two reinforcement brack-
ets must be attached directly above the universal module.
Using the supplied self-tapping screws, the module is
screwed to each of the four points with the wall profiles.
The module feet are at the front under the horizontal
C-profile and can be dowelled to the floor.
Module attachment with installation in a floor-to-ceiling C-profile metal stud wall
Follow the installation instructions for the dry-wall system
used.
Installation in floor-to-ceiling metal stud wall
with UA-profiles
Installation in a floor-to-ceiling UA-profile metal stud wall
If particularly wide or high walls have a higher rigidity,
UA-profiles (DIN 18182 part 1) can be used instead of
C-profiles. This measure is only relevant for toilet and bidet
modules.
For a disabled toilet facility only UA-profiles may be used
for the front and rear struts for strength reasons. The
installation of toilet facilities in public places for disabled
and elderly people must be carried out in accordance with
DIN 18040-1.
To attach a TECElux module 200 or 400, two holes (8 mm)
must be drilled on both sides of the TECElux module frame
at a distance of 15 and 390 mm beneath the upper edge
of the module.
The module is then attached to the UA profile using
mounting set (9380006).