background image

9

PIN code changing

1  Turn the ignition on Enter the PIN code

Press the Programming button 14 times. Wait for Immobilizer’s 

confirmation by 1 audible signal.

3  Set the new PIN code by using any combination of buttons 

perceived by the Immobilizer (see Integrator files). When 

entering a new PIN code, each pressing perceived by the Im-

mobilizer is confirmed by the audible signal for further control

-

ling assistance.

Wait for confirmation by 1 audible signal

5  Re-enter the new PIN code.

Wait for confirmation:

◊ 

2 audible signals and a sound trill mean that the PIN code 

has been changed and the Immobilizer has left the PIN 

code changing mode.

◊ 

Sound alert means that the PIN code has not been 

changed and the Immobilizer has left the PIN code 

changing mode. A mistake has been made when entering 

the new PIN code confirmation and it is necessary to re

-

peat the PIN code changing procedure starting from p. 1.

You can exit the PIN code changing mode anytime by turning 

the ignition off.

Programming button changing

Reset all settings to factory default.

2  Interface the Immobilizer with the vehicle.

If analog steering wheel buttons are used please define them 

(see above for the description of this procedure).

4  In order to assign any of the buttons perceived by the Immo-

bilizer as the Programming button, press the selected button 

and hold it for longer than 5 seconds until a long audible signal 

will be heard

Programming button can be assigned within 15 minutes 

after Immobilizer interfacing with the vehicle.

Programming examples

Example 1

Objective:

 You would like to change the factory settings of the Im-

mobilizer: set output No. 2 Engine locking to control the normally 

open relay.

Execution:

1  Turn the ignition on.

Enter the PIN code and wait for confirmation.

Enter Menu 1 by pressing and releasing the Programming 

button 10 times. If you have performed all the actions 

correctly, the Immobilizer will notify you of it with 3 audible 

signals.

According to Immobilizer hardware functions configuring 

(Menu 1) option No. 3 Engine locking is to be selected. To do 

so, press and release the Programming button 3 times. 

The Immobilizer will inform you on the selected menu option 

number by series of 3 audible signals.

5  Enter option No. 3 by pressing and holding the brake pedal. 

The Immobilizer will inform you on the option setting 

by repeated double audible signals because the current 

(factory set) option setting is “normally closed relay control”.

6  Select “the normally open relay control” by pressing 

and releasing the Programming button twice, for the second 

setting is followed by the third. The Immobilizer will inform 

you on the option setting with series of 1 audible signal.

7  Exit programming mode by turning the ignition off.

Example 2

Objective: 

You would like to change the factory settings of the Im-

mobilizer: to increase the Anti HiJack activation distance from 100 to 

300 meters.

Execution:

1  Turn the ignition on.

Enter the PIN code and wait for confirmation.

3  Enter the Immobilizer setting mode by pressing and releasing 

the Programming button 12 times (start doing it no longer 

than 10 seconds after entering the PIN code). If you have 

performed all the actions correctly, the Immobilizer will notify 

you of it with 4 audible signals.

4  Select the programming option for setting the Anti HiJack 

activation distance. According to Table 1 “Immobilizer 

settings” option No. 5 is to be selected. To do so, press 

and release the Programming button 5 times. The Immobilizer 

will inform you on the selected menu option number by series 

of 5 audible signals.

5  Enter option No. 5 by pressing and holding the brake pedal. 

The Immobilizer will inform you on the option setting 

by repeated single audible signals because the current 

(factory set) option setting is 1 (which stands for 100 meters 

distance).

6  Change option No. 5 setting by pressing and releasing 

the Programming button twice, therefore increasing 

the option setting by 2 (1+2=3). The Immobilizer will inform 

you on the option setting with series of 3 audible signals (300 

meters).

7  Exit the setting mode by turning the ignition off.

Resetting to factory default settings

Immobilizer has a procedure of resetting the programmable settings, 

where all vehicle model settings are removed from Immobilizer’s energy 

independent memory and PIN code and all other programming options 

are returned to factory original values.

If certain or all menu options are password protected (see Immobi-

lizer user settings programming (Menu 2), p. 2), only the options that 

are not prohibited will be reset. The remaining ones will keep their 

current values.

In order to reset to factory default:

Remove power supply from Immobilizer

2  Press and hold the integrated Programming button
3  Connect the power supply while holding the button. Immobilizer 

will emit irregular audible signals.

4  Release the button and wait until the signals stop.

Turn the ignition on and enter the current PIN code

*

.

6  An audible trill will be heard, which indicates that resetting 

to factory default has been completed.

7  Remove the power supply and disconnect the Immobilizer from 

CAN bus.

    If the Immobilizer is not installed in the vehicle, please enter 

the PUK code with the integrated Programming button.

Содержание Prizrak 510

Страница 1: ...510 T E C H N I C A L SPECIFICATION INTELLECTUAL S Y S T E M t h e f t p r e v e n t i o n PRIZRAK...

Страница 2: ...ecialists during Immobilizer installation or by you during day to day vehicle use Factory default settings PIN code 2 is entered with the Programming button see Inte grator files Upon Immobilizer inst...

Страница 3: ...ver warning on the necessity of entering the PIN code 10 seconds It is carried out by an audible sound alert Warning the other drivers on the road on the possible hazardous situation due to the upcomi...

Страница 4: ...s used for alternate hazard lights control in vehicles that do not support CAN bus control 2 Useful current of output No 6 depends on connected load of the negative outputs 3 Input No 8 is to be conne...

Страница 5: ...nds with the subgroup number 2 Forced interfacing This algorithm is used in extraordinary cases Programming is carried out with the integrated Programming button Prior to interfacing procedure initiat...

Страница 6: ...in order to remove prohibition see below 4 Admin prohibition is set for all menu options Password needs to be entered in order to remove prohibition Settings 1 Public and 2 OFF can be set with Progra...

Страница 7: ...g the option setting number with series of 9 audible signals Release the brake pedal the Immobilizer will indicate menu option number If the brake pedal is released prior to the but ton is pressed the...

Страница 8: ...mmobilizer feature on or off p 2 Anti HiJack feature allows turning the Anti HiJack feature on or off p 3 Speed control allows setting the lock activation algorithm for Immobilizer and Anti HiJack fea...

Страница 9: ...and releasing the Programming button twice for the second setting is followed by the third The Immobilizer will inform you on the option setting with series of 1 audible signal 7 Exit programming mode...

Страница 10: ...ith port 1 Compact disc 1 Connection scheme 1 User manual 1 Warranty certificate 1 Reminder card 1 Packaging 1 Technical characteristics Parameter Value Power supply voltage V 9 15 Maximum current dra...

Страница 11: ...11...

Страница 12: ...factured by TEC Electronics Ltd The product is manufactured in accordance with TC 4372 008 78025716 11 Certificate of conformity No POCC RU AB75 B00423 The product corresponds with the requirements of...

Отзывы: