FanControl‑GSM v2
6
•
When connecting the module to the vehicle’s CAN-bus in series, CAN2 or CAN3 (depends
on a vehicle) is connected to the side of the vehicle’s CAN-bus which is directly
connected to the climate control unit. CAN 1 is connected to the side of the vehicle’s
CAN-bus which is pointed in the opposite direction.
•
The installation manuals are available at www.tecel.ru/en/
Installing and adjusting the external temperature sensors
The operating algorithms of the module depend on the engine temperature, interior temperature
and the ambient temperature. This data is analyzed and is used by the module to start an engine
heater by temperature, to operate an aftermarket engine heater in the auxiliary heating mode; to
display this information in the mobile app and inform users via calls or SMS.
The module is able to receive the temperature data:
1.
Form the vehicle’s CAN-bus — only when the ignition is turned on.
2.
From the engine heater temperature sensor — only when the heater is running and if the
module controls the heater via the digital data bus.
3.
From the external temperature sensor — this sensor transmits data regardless of the igition
status or the engine heater status.
Before fitting the module to a vehicle we recommend to clarify:
1.
Wheather the module is able to receive the temperature data from the CAN-bus of a certain vehicle.
2.
Whether the owner of the vehicle is planning to use the heater in the auxiliary heating mode.
To implement this feature, the module needs data on the outside temperature which can be
received from the CAN-bus and from the external temperature sensor.
3.
Whether the owner prefers that the heater would automatically shutdown when the
engine temperature reaches a certain value and the climatic system would automatically
be activated by a certain engine temperature too. The module must receive the engine
temperature while the vehicle’s ignition is off in order to activate these operating modes. The
module is able to get this data from the heater if connected to it via the W-bus digital bus.
4.
Whether the owner would like to overview the engine temperature at all times independantly
from the engine or heater state.
You have to decide whether it is necessary or not to install the external sensors keeping in
mind the vehicles make, model and the owner’s wishes and preferences.
Setup
The module can be connected to a PC via a micro USB cable (figure 3) in order to update the
firmware, setup a vehicle model, activate the auxiliary heating mode, adjust the operating time
and etc. All these adjustments are performed in the TECprog software (available for download at
www.tecel.ru/en/
). Likewise, the module can be adjusted by using the built-in programming/reset
button (hereinafter-PB).
Red LED (GSM)
Green LED (Programming mode)
Micro-USB
PB
Blue LED (GPRS)
Figure 3. FanControl-GSM
Содержание FanControl-GSM
Страница 1: ...www tecel ru FanControl GSM v2...