FanControl‑GSM v2
11
Programming sequence
1.
Select a required option and press the PB the number of times corresponding to the «Menu
code» in the Table 5. The green LED will inform about the current option value.
2.
To change the option value, press the PB the number of times required to advance from the
current value to a desired one. Keep in mind that after the last value of an option goes the
very first one.
The module automatically exits the programming mode and saves all settings in a nonvolatile
memory if the ignition is turned OFF or the programming button is not pressed during 15 seconds.
The green LED fleshes 4 times if the settings are saved successfully; 1 long LED flash means an
error.
Resetting to default values
There is a special procedure designed to reset the module to default settings. After resetting the
module, the non-volatile memory of the FanControl module is cleared of all non-default values.
To reset the module:
1.
Disconnect the module from power source and CAN-bus.
2.
Press and hold the PB;
3.
Holding the PB pressed, supply power to the module (CAN bus should not be connected);
Wait for short LED flashes;
4.
Disconnect the module from power, release the PB.
Table 6. Technical data and operating conditions
Characteristic
Value
Power, V
9 ... 15
Maximum current consumption in active mode, mA
500
Maximum current drain in standby mode, mA
10
Maximum operating temperature,
°
C
–40 ... +85
Maximum relative humidity, %
95
Table 7. Package
Name
Amount, pcs.
Main unit
1
Wire harness
1
Temperature sensor
2
Enclosure TEC-0500
1
Manual
1
Package
1