FanControl‑GSM v2
10
Menu
Menu
code
Factory
default Note
Ability to customize an
operating mode of the
climate control system
*
22
1
1 — enabled; 2 — disabled
Climatic system turn on
conditions
***
26
1
1 — Simultaneousely with the engine heater
2 — Turn on with a delay after the engine heater
is started
3 — Turn on by certain engine temperature
4 — Turn on after a delay or by certain engine
temperature (depending on what happens first)
5 — Climatic system inactive
Delay before Climatic
system activation
***
28
2
1 – 5 min; 2 – 10 min; 3 – 15 min; 4 — 20 min;
5 — 25 min; 6 — 30 min
Engine temperature to
acitvate the climate
system
***
30
2
1 — 30°C; 2 — 40°C; 3 — 50°C; 4 — 60°C;
5 — 70°C; 6 — 80°C
Output settings № 11
36
1
1 — Heater operation (status).
The output generates a constant level signal
while an engine heater is running (If it is activated
with FanControl).
2 — Control of a recirculating pump.
The output generates a constant level signal
while the engine heater is running and within
2 minutes after the heater is deactivated. The
signal is formed if the heater was activated by
FanControl.
3 — Interior ventilation running (status).
The output generates a constant level signal
while the interior ventilation is running (If the
heater was activated by FanControl).
4 — Ignition imitation.
The output generates a pulse signal during 5 sec.
The output stops generating the signal earlier if
the FanControl module detects that the ignition
has been turned OFF or the heater has shutdown.
5 — PTC air heaters control.
The output generates a constant level signal if
the engine heater is running. The output stops
generating the signal after the engine heater
is turned OFF. The output doesn’t generate
any signal if the auxiliary heating mode was
activated.
6 — Cooling system circuit switching valve
control.
The output generates a constant level signal
after turning ON the engine heater. The output
stops generating the signal in 20 minutes after
the engine heater is turned off. If the engine is
started before 20 minutes expire – the signal will
vanish in 5 minutes. If the engine has been shut
down before 5 minutes expire – the module will
continue generating the signal for 20 minutes.
Output settings № 23
38
Engine heater automatic
shutdown
44
2
1 – After the driver’s door is opened or the brake
pedal is pressed.
2 – After the ignition is turned ON.
*
Used only in special cases. Check documentation to see which vehicles require these settings (www.tecel.ru\en\).
**
Sensor is installed if there is no data in the CAN-bus.
***
Engine temperature for climate system activation.