64
D/A Zero Setting (W33)
W 3 3 0 0 0 0 0 0 CR LF
sign bit
Plus: 0
Minus: -
Set value without
decimal point
(5 digits max)
D/A Full-Scale Settings (W34)
(Write-protected, read only)
W 3 4 0 0 0 0 0 0 CR LF
sign bit
Plus: 0
Minus: -
Set value without
decimal point
(5 digits max)
BEEP (W35)
W 3 5 0 0 0 0 0 0 CR LF
0: OFF
1: ON
Select Data Output (W36)
W 3 6 0 0 0 0 0 0 CR LF
0: Reference the display; hold value is
sent in hold mode
1: Reference the input; input value is
sent in hold mode
11-9. Set-value retrieval command
You can retrieve a set value by using the following command.
Request
W
CR
Response
W
CR LF
Setup value No.
Setup value No.
Same as data in set
command