11
3. Connections
3-1. Connecting to I/O terminal blocks
3-1-1. Connecting to sensor I/O terminal block
The TD-260T uses a 2-piece sensor input/output terminal
block.
To connect wires to the provided connector BCZ 3.81/07/180F
SN BK BX and then the connector to the terminal block, use
the provided flathead micro screwdriver.
If you want to use a screwdriver other than the provided
screwdriver, be sure to use a flathead screwdriver with teeth
not exceeding either 2.5 mm in width or 0.4 mm in thickness.
1. Strip off about 5 mm of the insulation from an end
of each wire you connect, and then gently twist each
bare end.
Use wires 0.2 to 1.5 mm
2
in cross-sectional area (28 to 16
AWG).
Approx. 5 mm
loosen
tighte
n
2. While keeping each bare end twisted, insert it into
the corresponding hole.
3. Secure each wire end to the hole by using the
flathead screwdriver.
4. Lightly pull each wire and make sure that they are
securely clamped.
5. Plug the wired connector into the terminal block in
the TD-260T, and then secure the connector plug to
the terminal block with screws.
3-1-2. Connecting to control I/O terminal block
The TD-260T uses a 2-piece control input/output terminal
block.
To connect wires to the provided connector B2L 3.50/18/180F
SN BK BX and then the connector to the terminal block, use
the provided flathead micro screwdriver.
If you want to use a screwdriver other than the provided
screwdriver, be sure to use a flathead screwdriver with teeth
not exceeding either 2.5 mm in width or 0.4 mm in thickness.
1. Strip off about 7 to 8 mm of the insulation from an
end of each wire you connect, and then gently twist
each bare end.
Use wires 0.13 to 1.0 mm
2
in cross-sectional area (28 to 18
AWG).
Screwdriver
insertion hole
(square)
Wire insertion hole (round)
Approx.
7-8 mm
2. Insert the screwdriver into the square holes next to
the wire insertion holes to enlarge the clamp areas.
3. While keeping each bare end twisted, insert it into
the corresponding hole, and then secure it to the
hole.
4. Lightly pull each wire and make sure that they are
securely clamped.
5. Plug the wired connector into the terminal block in
the TD-260T, and then secure the connector plug to
the terminal block with the screws.