408-35043
Rev
D
8
of 30
Figure 9: Mounting a feed cam on 30-mm [1
⅛
-in.] stroke machine
1
Mechanical pre-feed cam
2
Mechanical
post-feed cam
3
Air-feed pre- or post-feed cam
4
Mounting screw
NOTE
Pacific applicators can only be used with 30-mm stroke machines. They have only the 30-mm feed cam mounting positions on
the applicator ram.
NOTE
The recommended setup for mechanical end-feed applications is post-feed. The applicator can be configured for pre-feed, but
this causes problems with some applications. Feed issues or terminal jamming can occur in the mechanical pre-feed
configuration.