background image

INSTALLATION | WIRING GUIDE

 

AST Pressure Sensors 

 

TE CONNECTIVITY SENSORS 

/// INSTALLATION | WIRING GUIDE             

12//2018

 

Page 3 

Cable / Hookup

 

Wire Connections

 

Standard Cable 

 

Conduit with Cable 

 

 

 

AST Electrical Connection Option 

”A, B, C, D” 

 

“L, M, N, P” 

Gauge Wire 

24 AWG 

 

24 AWG 

 

Output Type 

Green

 

Black

 

Red

 

White 

mV & 4-Wire Voltage 

+S 

GND 

+V 

-S 

3 Wire Voltage 

N/C 

GND 

+V 

4-20mA (2 wire loop powered) 

N/C 

-V 

+V 

N/C 

 

 

 

 

 

CSA Certified Sensors

 

Output Type

 

Green

 

Black

 

Red

 

White 

3 Wire Voltage 

Case 

GND 

+V 

4-20mA (2 wire loop powered) 

Case 

-V 

+V 

N/C 

NOTICE FOR NON-INCENDIVE SENSORS INSTALLED IN [CLASS I, DIV 2, GROUPS A,B,C,D] 

- Suitable for use in [Class I, Division 2, Groups A, B, C And D] Hazardous Locations, or Non Hazardous Locations only. 

Explosion Hazard  

- Do not disconnect equipment while the circuit is live or unless the area is known to be free of ignitable concentrations. 

Explosion Hazard  

- Substitution of any component may impair suitability for [Class I, Division 2] 

NOTICE FOR INTRINSICALLY SAFE SENSORS 

- Refer to the Intrinsically Safe Installation Manual for barrier installation information 

 

 

+V 

Voltage Supply 

-V 

4-20mA Electrical Ground / Signal [see schematic] 

Voltage Output Signal 

GND 

Voltage Electrical Ground 

Case 

Case / Earth Ground 
(Do not connect or tie the case ground to the electrical ground) 

N/C 

Not Connected 

 

Содержание AST20PT

Страница 1: ...IN Form A Form C 5 Bendix 6 Pin 4 Pin 6 Packard Metri Pack 150 7 Minifast and M12x1 8 DT04 DEUTSCH 6 Pin 4 Pin 9 Molex 10 Pressure Temperature Transmitter Wiring Cable or Wire Pressure Temp 11 DIN Con...

Страница 2: ...n death or serious injury CAUTION used with the safety alert symbol indicates a hazardous situation which if not avoided could result in minor or moderate injury Wiring Schematics Output mV Voltage 0...

Страница 3: ...INSTALLED IN CLASS I DIV 2 GROUPS A B C D Suitable for use in Class I Division 2 Groups A B C And D Hazardous Locations or Non Hazardous Locations only Explosion Hazard Do not disconnect equipment wh...

Страница 4: ...ns Output Type Green Black Red White Voltage Case GND V Supply S 4 20mA 2 wire loop powered Case V Supply V Supply N C NOTICE FOR INTRINSICALLY SAFE SENSORS Refer to the Intrinsically Safe Installatio...

Страница 5: ...ide Pin Pin 1 Pin 2 Pin 3 Wide Pin 3 Wire Voltage V GND S Case S GND V Case 4 20mA 2 wire loop powered V GND Case N C N C GND V Case NOTICE FOR NON INCENDIVE SENSORS INSTALLED IN CLASS I DIV 2 GROUPS...

Страница 6: ...Pin A Pin B Pin C Pin D mV 4 Wire Voltage V S S GND N C Case V S S GND 3 Wire Voltage V S N C GND N C Case V S N C GND 4 20mA 2 wire loop powered V GND N C N C N C Case V GND N C N C V Voltage Supply...

Страница 7: ...he Intrinsically Safe Installation Manual for barrier installation information Output Type Pin A Pin B Pin C mV 4 Wire Voltage N A N A N A 3 Wire Voltage GND V S 4 20mA 2 wire loop powered V V N C V V...

Страница 8: ...Pin 3 Pin 4 mV 4 Wire Voltage 000 V S V S V S S GND 3 Wire Voltage 000 V S V Case V N C GRD S 4 20mA 2 wire loop powered 000 V N C V Case V N C V N C Output Type w Option Codes Code Pin 1 Pin 2 Pin 3...

Страница 9: ...n Option K Z Output Type Pin A Pin B Pin C Pin 1 Pin 2 Pin 3 Pin 4 mV 4 Wire Voltage V GND S S 3 Wire Voltage V GND S V GND S N C 4 20mA 2 wire loop powered V V N C V V N C N C V Voltage Supply V 4 20...

Страница 10: ...in 08 50 0114 Output Type Pin 1 Pin 2 Pin 3 Pin 4 mV 4 Wire Voltage V S S GND V Voltage Supply V 4 20mA Electrical Ground Signal see schematic S Voltage Output Signal GND Voltage Electrical Ground Cas...

Страница 11: ...hite 3 Wire Voltage Temp out V in V in Press out 4 20mA 2 wire loop powered Temp Press Press Temp NOTICE FOR HAZARDOUS AREA SENSORS AST46PT Refer to operating instructions for installation information...

Страница 12: ...2 Pin 3 Wide Pin Pin 1 Pin 2 Pin 3 Wide Pin 3 Wire Voltage V in V in Press out Temp out Press out V in V in Temp out 4 20mA 2 wire loop powered Press Press Temp Temp Press Press Temp Temp V Voltage S...

Страница 13: ...Temp N C N C M12x1 4 Pin DEUTSCH DT04 4 Pin AST Electrical Connection Option Y Z Pin 1 Pin 2 Pin 3 Pin 4 Pin 1 Pin 2 Pin 3 Pin 4 3 Wire Voltage V in Temp out V in Press out V in V in Press out Temp ou...

Страница 14: ...drawings illustrations and schematics which are intended for illustration purposes only is believed to be reliable However TE Connectivity makes no warranties as to its accuracy or completeness and di...

Отзывы: