![TE Connectivity AST20PT Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/te-connectivity/ast20pt/ast20pt_installation-and-wiring-manual_3906247002.webp)
INSTALLATION | WIRING GUIDE
AST Pressure Sensors
TE CONNECTIVITY SENSORS
/// INSTALLATION | WIRING GUIDE
12//2018
Page 2
Important Safety Instructions
This is the safety alert symbol. It is used to alert you to potential personal
injury hazards. Obey all safety messages that follow this symbol to avoid
possible injury or death.
DANGER
indicates a hazardous situation which, if not avoided,
will result in death or serious injury.
WARNING
indicates a hazardous situation which, if not avoided,
could result in death or serious injury.
CAUTION
used with the safety alert symbol, indicates a hazardous
situation which, if not avoided, could result in minor or moderate injury.
Wiring Schematics
Output
mV
Voltage
0.5-4.5V ratiometric
1-5V, 1-6V, 0-5V
0-10V, 1-10V
Supply Voltage
5VDC typ., 10VDC max.
5VDC ± 0.01V
10-28VDC
15-28VDC
Output Load
>1 MΩ
>10 KΩ
>10 KΩ
>10 KΩ
Operating Temperature
-40 to 105ºC
-40 to 85ºC
-40 to 85ºC
-40 to 85ºC
Output
4-20mA
Mechanical Installation
Supply Voltage
10-28VDC
Use the hex flats closest to the process connection for installation into the
process. For conduit connections, hold the product at the hex closest to
the conduit connection.
Output Load
0-800Ω
Operating Temperature
-40 to 85ºC