![TE Connectivity AST20PT Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/te-connectivity/ast20pt/ast20pt_installation-and-wiring-manual_3906247006.webp)
INSTALLATION | WIRING GUIDE
AST Pressure Sensors
TE CONNECTIVITY SENSORS
/// INSTALLATION | WIRING GUIDE
12//2018
Page 6
Bendix™
6 Pin MIL-C-26482 (REF. MS3113)
4 Pin MIL-C-26482 Series 1
(REF. MS3113)
AST Electrical Connection Option
”R”
”S”
Mates w/
PT06A-10-6S
PT06A-8-4S
AST Mating Connector Part #
A04235
N/A
NOTICE FOR INTRINSICALLY SAFE SENSORS - Refer to the Intrinsically Safe Installation Manual for barrier installation information
Output Type
Pin A
Pin B
Pin C
Pin D
Pin E
Pin F
(SS
only)
Pin A
Pin B
Pin C
Pin D
mV & 4-Wire Voltage
+V
+S
-S
GND
N/C
Case
+V
+S
-S
GND
3 Wire Voltage
+V
S
N/C
GND
N/C
Case
+V
S
N/C
GND
4-20mA (2 wire loop powered)
+V
GND
N/C
N/C
N/C
Case
+V
GND
N/C
N/C
+V
Voltage Supply
Option Code - For Special Wiring Requests
-V
4-20mA Electrical Ground / Signal [see
schematic]
Pin A
Pin B
Pin C
Pin D
Pin E
Pin F
(-SS only)
S
Voltage Output Signal
000
+V
+S
-S
GND
N/C
Case
GND
Voltage Electrical Ground
115
+S
-S
GND
+V
N/C
Case
Case
Case / Earth Ground
(Do not connect or tie the case ground to
the electrical ground)
164
+S
-S
+V
GND
N/C
Case
N/C
Not Connected
292
+V
GND
+S
-S
N/C
Case