![TE Connectivity AST20PT Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/te-connectivity/ast20pt/ast20pt_installation-and-wiring-manual_3906247008.webp)
INSTALLATION | WIRING GUIDE
AST Pressure Sensors
TE CONNECTIVITY SENSORS
/// INSTALLATION | WIRING GUIDE
12//2018
Page 8
Minifast™
M12x1
Minifast™
M12x1
AST Electrical Connection Option
”4”
”Y”
NOTICE FOR INTRINSICALLY SAFE and NON-INCENDIVE SENSORS - Refer to the Intrinsically Safe and Non-Incendive Installation
Manuals for barrier installation information.
Output Type
Code
Pin 1
Pin 2
Pin 3
Pin 4
Pin 1
Pin 2
Pin 3
Pin 4
mV & 4-Wire Voltage
000
-V
+S
+V
-S
+V
+S
-S
GND
3 Wire Voltage
000
-V
S
+V
Case
+V
N/C
GRD
S
4-20mA (2 wire loop powered)
000
-V
N/C
+V
Case
+V
N/C
-V
N/C
Output Type w/ Option Codes
Code
Pin 1
Pin 2
Pin 3
Pin 4
4-20mA (2 wire loop powered)
615
-V
+V
N/C
Case
3 Wire Voltage
607/617
S
+V
Case
-V
+V
Voltage Supply
-V
4-20mA Electrical Ground / Signal [see schematic]
S
Voltage Output Signal
GND
Voltage Electrical Ground
Case
Case / Earth Ground
(Do not connect or tie the case ground to the electrical ground)
N/C
Not Connected
Hirschmann, Bendix, Metri-Pack, Minifast and Molex are trademarks of their respective owners.