3. Check the clearance between the bottoming 
surfaces of the crimping dies. If the clearance is 
.025 mm [.001 in.] or less, the ratchet is satisfactory. 
If clearance exceeds .025 mm [.001 in.], the ratchet 
is out of adjustment, and must be repaired. Refer to 
Section 8, REPLACEMENT AND REPAIR. If the 
tool conforms to these inspection procedures, 
lubricate it with a THIN coat of any good SAE‡ 20 
motor oil and return it to service.

8. REPLACEMENT AND REPAIR

Replacement parts are listed in Figure 13. Parts other 
than those listed in Figure 13 should be replaced by 
Tyco Electronics to ensure quality and reliability of the 
tool. Order replacement parts through your TE 

Representative, or call 1-800-526-5142, or send a 
facsimile of your purchase order to 1-717-986-7605, or 
write to:

CUSTOMER SERVICE (038-035)

TYCO ELECTRONICS CORPORATION

PO BOX 3608

HARRISBURG PA 17105-3608

9. REVISION SUMMARY

Since the previous release of this sheet, the new 
company logo was applied.

TOOL NUMBERS AND REPLACEMENT PART NUMBER

ITEM

DESCRIPTION

591 SHORT HANDLE

59250 LONG HANDLE

59275 SHORT HANDLE 

59300 LONG HANDLE

69692-1

LONG HANDLE

69693-1

LONG HANDLE

QTY PER

ASSY

1

Support, Locator

---

---

59755-1

59755-2

1

2

Screw

---

---

1-21002-3

1-21002-3

2

Figure 13

Содержание 59275

Страница 1: ...G Radiation Resistant Terminals and Splices on stranded copper wire sizes 26 through 14 PLASTI GRIP Terminals on solid or stranded copper wire sizes 22 through 14 PLASTI GRIP Butt Splices on solid or...

Страница 2: ...408 1610 2 of 11 Rev M Figure 2 Cont d...

Страница 3: ...st fully closed Crimp the color coded terminals and splices in the matching color coded portion of the tool Refer to Section 3 3 Place terminal in crimping dies so that terminal tongue slides under lo...

Страница 4: ...sts against the recessed surface of the locator as shown in Figure 5 Spare Wire Caps Insulation Adjustment Indicator at Position 4 Wire Barrel Locator Raise Locator So the End of the Cap Rests Against...

Страница 5: ...p of tool and turn indicator to Position 4 2 Place terminal or splice in tool dies 3 Insert UNSTRIPPED wire into ONLY the insulation barrel see Figure 3 or Figure 4 of terminal or splice 4 Perform a c...

Страница 6: ...ustment indicator in Position 4 for wire having a large insulation diameter 2 Set insulation adjustment indicator in Position 3 for wire having a medium insulation diameter 3 Set insulation adjustment...

Страница 7: ...degreasing compound with a lint free cloth When degreasing compounds are not available tool may be wiped clean with a lint free cloth Relubricate tool as instructed in Paragraph 7 3 before placing it...

Страница 8: ...ring loaded locator up and hold gage in straight alignment with the crimping chamber Carefully try to insert without forcing the GO element See Figure 12 Detail A The GO element must pass completely t...

Страница 9: ...1 position 3 Insert proper solder slug into one crimp chamber see Figure 9 and Figure 10 and cycle tool 4 Measure the compressed solder slug for the wire barrel crimping chamber and check for complia...

Страница 10: ...en the bottoming surfaces of the crimping dies To inspect the CERTI CRIMP hand crimping tool ratchet control 1 Perform a crimp using the largest wire size for your tool 2 While holding the wire in pla...

Страница 11: ...r than those listed in Figure 13 should be replaced by Tyco Electronics to ensure quality and reliability of the tool Order replacement parts through your TE Representative or call 1 800 526 5142 or s...

Отзывы: