2.2 Electrical Safety
The equipment is connected to an AC mains electricity supply. Before
undertaking any maintenance or repair, always turn off the equipment and
ensure it is isolated from the AC supply.
Allow the equipment to cool.
DO NOT CARRY OUT AN INSULATION RESISTANCE CHECK USING A
PORTABLE APPLIANCE TEST UNIT. THIS WILL RESULT IN DAMAGE TO
THE EQUIPMENT.
High voltage TESTING: Do NOT do the Test without the authorization of TE
(protection circuits fitted to this equipment may be damaged...)
INSULATION RESISTANCE TESTING: Do NOT exceed 250V DC (protection
circuits fitted to this equipment may be damaged).
Power connections for the Processor must conform to local standards and
regulations.
Potentially hazardous voltages are exposed if the equipment
’s
panels are
removed while it is powered-up. Do not use the equipment unless all external
panels are securely in place.
The equipment input supply has double-pole fusing (Line and Neutral) and must
be connected to an earthed power supply.
Use only specified fuse types and ratings.
Terminal customer should install overcurrent protective device. (3A)
Terminal customer should apply the power with overvoltage and undervoltage
protection.
Содержание 2376800-1
Страница 55: ...RBK X1C PN 2376800 1 Page 54 Rev A Dec 2020 6 Schematic Diagram...
Страница 56: ...RBK X1C PN 2376800 1 Page 55 Rev A Dec 2020...
Страница 57: ...RBK X1C PN 2376800 1 Page 56 Rev A Dec 2020...
Страница 58: ...RBK X1C PN 2376800 1 Page 57 Rev A Dec 2020...
Страница 59: ...RBK X1C PN 2376800 1 Page 58 Rev A Dec 2020...
Страница 60: ...RBK X1C PN 2376800 1 Page 59 Rev A Dec 2020...
Страница 61: ...RBK X1C PN 2376800 1 Page 60 Rev A Dec 2020...
Страница 62: ...RBK X1C PN 2376800 1 Page 61 Rev A Dec 2020...
Страница 63: ...RBK X1C PN 2376800 1 Page 62 Rev A Dec 2020...
Страница 64: ...RBK X1C PN 2376800 1 Page 63 Rev A Dec 2020 7 Pneumatic Diagram...