409-5861
6 of 26
Rev B
The CPU/motor controller is located under the top cover of the terminating machine. The controller is a modular
unit that contains all of the electronics necessary to operate the terminating machine.
There are seven circular plastic connectors (CPC) located on the electrical control box. See Figure 4. The
interface connection to the crimp quality monitor (CQM), connector J1, is located on the left side of the
terminating machine, just below the top cover. The remaining six are located along the right side of the
terminating machine, just below the top cover. Starting at the front of the terminating machine (immediately
behind the air feed solenoid) are connections for: the terminating machine interface (J2), the parent machine
interface (J3), the manual cycle button (J4), the main drive motor connector (J5), the main ac power connector
(J6) and the crimp quality monitor ac power connector (J7).
DANGER
STOP
The CPU/motor controller unit contains high voltages which can maintain power even after the power supply has been
disconnected from the terminating machine. When servicing the controller unit, exercise caution when handling the unit to
avoid electrical shock.
Figure 4
Terminating
Machine Interface
(J2)
Parent Machine
Interface
(J3)
Manual Cycle Button
(J4)
Main Drive Motor
Connector
(J5)
Main AC Power
Connector
(J6)
Crimp Quality
Monitor (CQM)
AC Power Connector
(J7)
Note: Interface Connection (J1) to crimp quality monitor (CQM) is located
on the left side of the terminating machine.