background image

 

AN-000240

 

 

Document Number: AN-000240

 

Page 23 of 23

 

Revision: 2.0 

 

5

 

REVISION HISTORY 

 

Revision Date 

Revision 

Description 

09/10/2020 

1.0 

Initial Release 

09/30/2020 

1.1 

Revised Introduction. Added H/W preparation section. Revised plot explanation. 

01/15/2021 

1.2 

Added mounting req. Added custom tuning parameter explanation. Added Tuning Appendix. 

03/04/2022 

2.0 

Revised document for latest GUI release 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This information furnished by Chirp Microsystems

, Inc. (“

Chirp Microsystems

”) is believed to be accurate and reliable. However, no responsibility is assumed by 

Chirp 

Microsystems for its use, or for any infringements of patents or other rights of third parties that may result from its use. Specifications are subject to change without 
notice. Chirp Microsystems reserves the right to make changes to this product, including its circuits and software, in order to improve its design and/or performance, 
without prior notice. Chirp Microsystems makes no warranties, neither expressed nor implied, regarding the information and specifications contained in this document. 
Chirp Microsystems assumes no responsibility for any claims or damages arising from information contained in this document, or from the use of products and services 
detailed therein. This includes, but is not limited to, claims or damages based on the infringement of patents, copyrights, mask work and/or other intellectual property 
rights.  

Certain intellectual property owned by Chirp Microsystems and described in this document is patent protected. No license is granted by implication or otherwise under 
any  patent  or  patent  rights  of  Chirp  Microsystems.  This  publication  supersedes  and  replaces  all  information  previously  supplied.  Trademarks  that  are  registered 
trademarks are the property of their respective companies. Chirp Microsystems sensors should not be used or sold in the development, storage, production or utilization 
of any conventional or mass-destructive weapons or for any other weapons or life threatening applications, as well as in any other life critical applications such as 
medical  equipment,  transportation,  aerospace  and  nuclear  instruments,  undersea  equipment,  power  plant  equipment,  disaster  prevention  and  crime  prevention 
equipment.  

©2020 Chirp Microsystems. All rights reserved. Chirp Microsystems and the Chirp Microsystems logo are trademarks of Chirp Microsystems, Inc. The TDK logo is a 
trademark of TDK Corporation. Other company and product names may be trademarks of the respective companies with which they are associated. 

 

©2020 Chirp Microsystems. All rights reserved. 

Содержание DK-CH101

Страница 1: ...and information herein without notice Chirp Microsystems 2560 Ninth Street Ste 200 Berkeley CA 94710 U S A 1 510 640 8155 www chirpmicro com Document Number AN 000240 Revision 2 0 Release Date 03 04...

Страница 2: ...ware 5 2 1 2 Using SmartSonic Module Sensor 6 2 1 3 Flash SmartSonic FW 7 2 2 CH101 CHIRP SENSOR MODULE MOUNTING 8 3 GUI 9 3 1 LAUNCH GUI 9 3 2 GUI FIELDS AND WIDGETS 9 3 3 SETTINGS AND TUNING 10 3 3...

Страница 3: ...w the floor type detection demo hardware and software setup Run the floor type detection application Robofloor GUI Understand how to set the floor height and proper mounting Tune parameters and data o...

Страница 4: ...etailed module and module integration information The CH101 sensor a single pulse echo sensor is an ultrasonic transceiver that can transmit and receive ultrasound signals These sensors measure the ro...

Страница 5: ...Below is the list of available f w package s available The X in the file name is the version number The latest file should be provided Table 2 1 Available f w for Standalone Demo Description FW Floor...

Страница 6: ...ientation to prevent flex cable hitting other components a Sensor 0 J6 b CH101 Note Horn Housing may differ from picture 2 Move jumper to FTDI slot after board has been programmed 3 Connect all J3 jum...

Страница 7: ...o 7 application or use command prompt Download Atmel Studio from their website if needed Link https www microchip com mplab avr support atmel studio 7 3 Pull down the Tools menu Tools Device Programmi...

Страница 8: ...unting suggestions The mechanical integration guide listed in the Reference Documentation section can be reviewed for a deeper dive into the module assembly and further explanation on the requirements...

Страница 9: ...r Gui demo robofloor X X X Ensure proper firmware is flashed on SmartSonic 3 Launch floor_demo exe 4 Hit Connect and the detection will start 3 2 GUI FIELDS AND WIDGETS Figure 3 1 Robo Floor GUI Inter...

Страница 10: ...s algo configurations etc click the and Open documentation dropdown 3 3 SETTINGS AND TUNING The GUI is used to display real time plots and output numerical values of its scans with automatic auto or c...

Страница 11: ...le to the desired location with the horn housing facing downward to the floor surface The sensor must be facing the floor surface with no tilt or reflective surroundings For more information on module...

Страница 12: ...oundings For more information on module mounting refer to Section 2 2 2 In the unpacked folder RoboFloor_vX X X exe and in the GUI folder open Gui demo robofloor x x x 3 Click the settings icon to inp...

Страница 13: ...pical is 8 Start index of window before floor reflection Shift this setting to where ringdown begins or to desired starting point Customize ringdown length Define the size of ringdown window typical r...

Страница 14: ...er of samples Set the max number of samples to process typical value should cover the whole floor window Customize range threshold decay factor Decay factor of the threshold 0 100 Impacts short distan...

Страница 15: ...ins each of the display windows and widgets 3 4 1 Real Time Plots Magnitude Echoes measured by the sensor o Magnitude plot of range vs amplitude for the sensor Figure 3 8 Plot Magnitude Floor Metric D...

Страница 16: ...istance between floor and sensor o Plot of distance to floor over time for the sensor Figure 3 10 Plot Floor Range ASCAN Amplitude scan o Bright white areas in the plot represent high amplitude reflec...

Страница 17: ...such as a carpet will output a 0 while moving over a Hard Floor such as a hardwood floor will output a 1 Soft Floor Detection o Floor Type of 0 and a metric below the detection threshold will display...

Страница 18: ...ition from Soft Floor to Hard Floor Real time plot at time 0 being current value Hard Floor Detection o Floor Type of 1 and a metric below the detection threshold will display a Hard Floor along with...

Страница 19: ...3 Revision 2 0 Figure 3 14 Example of a Hard Floor output plot Real time plot at time 0 being current value Figure 3 15 Example of a plot of a transition from Hard Floor to Soft Floor Real time plot a...

Страница 20: ...NDIX 4 1 TROUBLESHOOTING BAD TUNING 1 Ringdown settings Example settings o Sensor Height 48mm o ringdown_start_idx 5 Issues o Latency affected o Bad data in the ringdown phase o Hard to distinguish fl...

Страница 21: ...Page 21 of 23 Revision 2 0 2 Floor Distance settings Example settings o Module mounted at 48mm o floor_start_idx 15 o Moved from hard to soft then back to hard surface Issues o Latency affected o Floo...

Страница 22: ...23 Revision 2 0 3 Module not set to proper floor distance Example settings o Sensor Height 25mm and 60mm o Module mounted at 48mm Issues o Floor detection accuracy o Floor type metric o Can detect th...

Страница 23: ...nt or from the use of products and services detailed therein This includes but is not limited to claims or damages based on the infringement of patents copyrights mask work and or other intellectual p...