2.1.2 Using SmartSonic Module Sensor
Setup instructions are below:
1.
Connect one end of the 8POS FFC cable to the Sensor-0 connector and the other into the CH101 module sensor. Check
flex orientation to prevent flex cable hitting other components.
a)
Sensor-0
–
J6
b)
CH101 - Note: Horn/Housing may differ from picture
2.
Move jumper to FTDI slot after board has been programmed
3.
Connect all J3 jumpers
4.
Connect USB cable from PC to FTDI-USB connector
5.
Toggle the switch from U15 to J6
(Sensor-0) - Note: U15 will use sensor on SmartSonic daughterboard
6.
Reset the board when changing any connections
Figure 2-2. SmartSonic Connections