background image

7

RFE1000 - CONNECTIONS FOR OPERATION

1. SINGLE UNIT OPERATION

1.1. Remote sensing*

Load line.

Up to 1V drop.

Sense lines

Twisted pairs

Load line.

Up to 1V drop.

LOAD

RFE1000

SIGNAL

RTN

ON/

OFF

+V

+S

-S

-V

J1-1

J-1

J-6

J1-2

+V

-V

Fig 1.1

*  In Local sense applications,  the +/- sense  have to be connected to the +/-V 

  terminals of the RFE1000 units before the operating the RFE1000 units. 

1.2. On/off control

1.3. Supervisory signals

Application

Monitoring

and Control

circuts

Note: AC_FAIL, DC_OK and TEMP.ALARM are open collector signals. See Table 1 

Fig 1.2

Fig 1.3

ON

OFF

RFE1000

ON/OFF J-6

SIGNAL_RTN

J-11

RFE1000

12V AUX

AC_FAIL

DC_OK

TEMP.ALARM

SIGNAL_RTN

10K 10K

10K

J1-4
J1-12
J1-5
J1-8
J1-11

Содержание RFE1600-12

Страница 1: ...ce Environmental These products are IPX0 and therefore chemicals solvents cleaning agents and other liquids must not be used Environment This power supply is a switch mode power supply for use in appl...

Страница 2: ...mechanical electric shock and fire hazard protection Energy Hazards The main output of this product is capable of providing hazardous energy 240VA Final equipment manufacturers must provide protection...

Страница 3: ...rmit t mit der EMV Richtlinie muss in der finalen Gesamtinstallation betrachtet werden Bitte kontaktieren Sie Ihr regionales TDK Lambda Vertriebsb ro im Falle von R ckfragen Umwelt Diese Produkte sind...

Страница 4: ...er Gefahr von mechanischen Risiken Stromschl gen und Brandschutz in dem Endger t vorgesehen werden Gefahren durch elektrische Energie Von bestimmten Modulen kann je nach Einstellung der Ausgangsspannu...

Страница 5: ...r votre bureau TDK Lambda le plus proche Environnement Ces produits sont IPX0 et donc on ne doit pas utiliser des produits chimiques solvants des produits de nettoyage et d autres liquides Environneme...

Страница 6: ...assurer la protection contre les chocs m caniques les chocs lectriques et l incendie Energies dangereuses Certains modules peuvent g n rer une nergie dangereuse 240 VA selon le r glage de tension de...

Страница 7: ...o a vostra disposizione per ulteriori ragguagli Condizioni ambientali Questi prodotti sono classificati come IPX0 dunque non devono essere utilizzati sostanze chimiche solventi prodotti per la pulizia...

Страница 8: ...ttriche e dai pericoli di incendio Pericoli energetici Alcuni moduli sono in grado di erogare energia pericolosa 240 VA a seconda della tensione in uscita impostata I produttori delle apparecchiature...

Страница 9: ...to con su oficina local de TDK Lambda Medioambiental Estos productos son IPX0 y por tanto no pueden utilizarse sustancias qu micas disolventes agentes de limpieza ni otros l quidos Medio ambiente Esta...

Страница 10: ...endios de protecci n mec nica contra descargas el ctricas y contra el peligro de incendios Peligros de energ a Algunos m dulos pueden generar energ a peligrosa 240VA dependiendo de la configuraci n de...

Страница 11: ...na instala o final Entre em contacto com seu escrit rio TDK Lambda mais pr ximo Ambiental Estes produtos s o IPX0 e como tal n o se devem utilizar qu micos solventes agentes de limpeza e outros l quid...

Страница 12: ...de de fornecer energia perigosa 240 VA de acordo com a configura o da tens o de sa da O equipamento final do fabricante deve garantir que o pessoal de assist ncia est protegido contra contactos inadve...

Страница 13: ...Possible via Vout Trim Potentiometer on PCB Refer to Instruction Manual 29 Front panel indicator DC OK Refer to Instruction Manual 30 I C Interface No 31 Operating temperature 0 50 C 100 load 50 C to...

Страница 14: ...s within safe limit Off approx 10 C below Thermal shut down The maximum sink current is 10mA and the maximum external voltage is 15V J1 2 Sense Negative sensing The S signal should be connected to the...

Страница 15: ...3 RFE1000 SERIES OUTLINE DRAWING...

Страница 16: ...conditions Indoor use Pollution degree 2 Max operational altitude 3000m above sea level Ambient temperature 10 C 50 C at 100 load up to 70 C with output de rating applied See Specification GROUNDING R...

Страница 17: ...sons the mains supply voltage fluctuations should not exceed 10 of nominal voltage ENERGY HAZARD The main output of RFE1000 units is capable of providing hazardous energy Due to hazardous energy level...

Страница 18: ...6...

Страница 19: ...se applications the sense have to be connected to the V terminals of the RFE1000 units before the operating the RFE1000 units 1 2 On off control 1 3 Supervisory signals Application Monitoring and Cont...

Страница 20: ...the same output voltage rating can be connected in parallel By connecting the CS signal between the paralleled units automatic current balance is achieved with 10 accuracy Derate the total output cur...

Страница 21: ...ed that diodes be connected in parallel with each unit output to prevent reverse voltage Each diode should be rated to at least the power supply rated output voltage and output current Diodes are user...

Страница 22: ...5 of rated Vo Off when output voltage Vout 80 5 of rated Vo 1 Forced air cooling allow minimum 50mm of unrestricted air space at the rear of the unit do not obsruct air flow to the unit front panel 2...

Страница 23: ...11...

Страница 24: ...12 IA714 04 01C...

Отзывы: