4
RFE1000 SAFETY INSTRUCTIONS
SAFETY APPROVALS
UL 60950-1 and CSA22.2 No.60950-1 - UL Recognized. C-UL for Canada.
IEC 60950-1 - CB Report and Certificate.
EN 60950-1 - CE mark.
Marking by the CE Symbol indicates compliance to the Low Voltage Directive of the European Union.
A “Declaration of Conformity” in accordance with the preceding directives and standards has been made and is on
file at our EU representative: TDK-Lambda Germany GmbH, Karl-Bold-Str. 40, D-77855 Achern.
A “Declaration of Conformity” may be accessed via company website www.emea.tdk-lambda.com/manual
SAFETY INSTRUCTIONS
CAUTION:
The following safety precaution must be observed during all phases of operation, service and repair of
this equipment. Failure to comply with the safety precautions or warnings in this document violates safety standards
of design, manufacture and intended use of this equipment and may impair the built-in protections within. TDK
Lambda shall not be liable for user’s failure to comply with these requirements.
Vorsicht:
Die folgenden Sicherheitsvorschriften müssen vor Inbetriebnahme und in jedem Betriebszustand bei
Service oder Reparatur beachtet werden. Missachtung der Sicherheitsvorschriften und Warnhinweise aus diesem
Handbuch führen zur Verletzung der bestehenden Sicherheitsstandards. Bei Betrieb des Gerätes ausserhalb dem
bestimmungsgemässen Einsatz können die im Gerät integrierten Schutzfunktionen beeinträchtigt werden. TDK-
Lambda ist nicht haftbar für Schäden, die durch Missachtung dieser Sicherheitsvorschriften entstehen können.
CAUTION: RFE1000 units are not authorized for use as critical component in nuclear control systems, life support systems or
equipment for use in hazardous environments without the express written approval of the managing director of TDK-Lambda.
Vorsicht:
Dieses Produkt ist nicht für die Verwendung als kritische Komponente in nuklearen Steuerungssystemen,
lebenserhaltenden Systemen oder Geräte für den Einsatz in gefährlichen Umgebungen, ohne die ausdrückliche
schriftliche Genehmigung durch TDK-Lambda zugelassen.
INSTALLATION (OVERVOLTAGE) CATEGORY& ENVIRONMENTAL CONDITIONS
The RFE1000 units have been evaluated to Overvoltage category II.
The RFE1000 units intended for use in the following operation conditions:
* Indoor use * Pollution degree 2 * Max. operational altitude: 3000m above sea level
*Ambient temperature: -10°C-50°C at 100% load, up to 70°C with output de-rating applied (See Specification)
GROUNDING
RFE1000 units are Class I products. To minimize electrical shock hazard, the RFE1000 units must be connected to
an electrical ground. The instruments must be connected to the AC power supply mains through a three conductor
power cable, with the ground wire firmly connected to an electrical ground (safety ground) at the power outlet. For
instruments designed to be hard-wired to the supply mains, the protective earth terminal must be connected to the
safety electrical ground before any other connection is made. Any interruption of the protective ground conductor or
disconnection of the protective earth terminal will cause a potential shock hazard that might cause personal injury.
Erdungskonzept:
Dieses Produkt ist ein Gerät der Schutzklasse 1. Zur Vermeidung von gefährlichen
Energieinhalten und Spannungen, ist das Gehäuse an eine Schutzerde anzuschliessen. Der PE-Anschluss ist an
einen festen Erder anzuschliessen. Bei Festverdrahtung des Gerätes ist sicherzustellen, dass der PE Anschluss
als erstes angeklemmt wird Jede mögliche Unterbrechung des PE-Leiters oder Trennung der PE Verbindung kann
einen möglichen elektrischen Schlag hervorrufen, der Personenschäden zur Folge hätte.
LIVE CIRCUITS
Operating personnel must not remove the RFE1000 units cover. No internal adjustment or component replacement is allowed by
non-TDK Lambda qualified service personnel. Never replace components with power cable connected. To avoid injuries, always
disconnect power, discharge circuits and remove external voltage sources before touching components. Restricted Access Area:
RFE1000 units should only be installed in a Restricted Access Area. Access should be available to service personnel only.
Spannungsführende Teile
Die Geräteabdeckung darf nicht durch Endanwender geöffnet werden. Interne Modifikationen, sowie Bauteileaustausch
ist nur durch TDK-Lambda qualifiziertes Personal erlaubt. Vor Austausch von Bauteilen ist das Netzkabel bzw. die
Versorgungsspannung zu trennen. Energieversorgungsanschlüsse sind immer zu trennen, um Personenschäden durch
gefährliche Energieinhalte und Spannungen auszuschliessen. Die Stromkreise sind zu entladen, externe Spannungsquellen sind
zu entfernen, bevor auf Bauteile bzw. Komponenten Ebene gearbeitet wird.
Содержание RFE1600-12
Страница 15: ...3 RFE1000 SERIES OUTLINE DRAWING...
Страница 18: ...6...
Страница 23: ...11...
Страница 24: ...12 IA714 04 01C...