620. Isolation Test
Isolation resistance between Output terminal is more than 100MΩ at 500VDC. For safety operation, voltage
setting of DC isolation tester must be done before the test. Ensure that the unit is fully discharged after the test.
■
Output terminal : 500VDC More than 100MΩ
621. Withstand Voltage
This series is designed to withstand 4.0kVAC between input and output, 2.0kVAC between input and
terminal, 1.5kVAC between output and terminal and 100VAC between output and PF, TOG, STB, CNT,
AC Fail, DATA, SG terminal each for 1 minute. In the withstand voltage tester, set current limit of the
withstand voltage tester at 20mA.The applied voltage must be gradually increased from zero to test value and
then gradually decreased for shut down. When timer is used, the power supply might be
damaged by high impulse voltage at switch on and off timing. Connection as follows.
■
Input Output : 4.0kVAC 1min
(
20mA
)
■
Output
–
TOG, etc. : 100VAC 1 min
(
20mA
)
20/28
+V
V
Output
Terminal
+Vm
+S
Vm
S
PC
CC
PV
COM
PF
AC Fail
CNT 1
+STB
CNT 2
STB
SG
TOG
+DATA
DATA
L
N
Input
Terminal
CN84
Isolation
Tester
+V
V
Output
Terminal
+Vm
+S
Vm
S
PC
CC
PV
COM
PF
AC Fail
CNT 1
+STB
CNT 2
STB
SG
TOG
+DATA
DATA
L
N
Input
Terminal
CN84
Withstand
Voltage
Tester
+V
V
Output
Terminal
+Vm
+S
Vm
S
PC
CC
PV
COM
PF
AC Fail
CNT 1
+STB
CNT 2
STB
SG
TOG
+DATA
DATA
L
N
Input
Terminal
CN84
Withstand
Voltage
Tester