background image

 

Page 

2

 of 

11

 

 

TDK-Lambda 

DBM20 

 

INSTRUCTION MANUAL

 

PA640-04-01B 

 

 

 

 

 CAUTION ON USE

 

 

When used in environment with corrosive gas (hydrogen sulfide, sulfur dioxide, etc.) , there is possibility that they might penetrate the product and lead to 
failure. 

 

When used in environments where there is conductive foreign matter or dust, there is possibility of product failure or malfunction. 

 

Provide countermeasure for prevention of lightning surge voltage as there is a risk of damage due to abnormal voltage. 

 

Connect together the frame ground terminal of the product and the ground terminal of the equipment for safety and noise reduction. If these ground is not 
connected together, there is a risk of electric shock. 

 

Take care not to apply external abnormal voltage to the input/output. Especially, applying reverse voltage or overvoltage more than the rated voltage to the 
input/output  as it may cause failure, electric shock or fire. 

 

Depending on product failure mode, there is possibility of hazardous voltage occurance at the input/output terminal. Therefore, the input/output of this 
product must be protected in the end use equipment to maintain ES1. 

 

This product contains a printed circuit board utilizing surface mounted devices. PCB stress such as bending, twisting, etc., could cause damage. Please handle 
with care. 

 
 

 NOTE 

 

When disposing product, follow disposal laws of each municipality.

 

 

 

Published EMI (RE) or immunity is the result when measured in our standard measurement conditions and may not satisfy specification when mounted and 
wired inside end-user equipment.Use the product after sufficient evaluation is done at the actual end-user equipment. 

 

When exporting our products, apply the necessary permissions as required by rules and regulations of  Foreign Exchange and Foreign Trade Control Act. 

 

Catalogue or contents of the instruction manual may be changed without a prior notice. Refer to latest catalogue or instruction manual. 

 

Reproduction or reprinting the instruction manual or its portion is not allowed without our permission. 

 

          PRECAUTIONS DE MONTAGE ET D’UTILISATION 

 

Respecter les connexions des borniers d’entrée/sortie décrites dans le manuel utilisateur avant de mettre sous tension. 

 

Ne pas utiliser ce produit dans un environnement exposé à un fort champ émectromagnétique, à des substances corrosives ou conductrices,  
à la lumière directe du soleil ou à la pluie et l’humidité. 

 

En cas d’installation dans un environnement où des particules conductrices, de la poussière ou des liquides peuvent être présents,  
merci d’installer des filtres afin de prévenir toute intrusion de corps étrangers à l’intérieur du produit et d’éviter pannes et dysfonctionnements. 

 

Ce produit est destiné aux équipements électroniques à usage general et il n’est pas conçu pour des applications à hauts risques (telles que les applications de 
sécurité ou de grande fiabilité. Même si une grande fiabilité ou une grande sécurité ne sont pas requises, ce produit ne doit pas être utilisé directement dans 
des applications présentant des risques sérieux pour la vie ou l’intégrité physique). Le principe de défaillance sécuritaire doit être appliqué à la conception 
(tels que l’installation de circuits ou de composants de protection). 

 

Connecter la masse du châssis et la borne de terre de l’équipenet pour la sécurité et la réduction de bruit. Si cette connexion n’est pas faite, il existe un risque 
de choc électrique. 

 

En fonction du type de défaillance, il eixte un possibilité de pr »sence d’une tension dangereuse sur les bornes de sortie. Ainsi, la sortie de ce produit doit être 
protégée dans l’équipement final pour conserver la TBTS. 

 
      

 LONG-TERM STORAGE METHOD AND LONG-TERM STORAGE PERIOD 

 

Please keep the product in carton box. 

 

Please do not apply excessive vibration, shock or mechanical stress applied directly to the product. 

 

Please keep away from direct sunlight.

 

 

Temperature and humidity should be within range of product specification (with no condensation)

 

 

For long-term storage temperature and humidity, the following conditions shall be used as a guideline :

 

Temperature range : 5℃

30℃ 

Humidity range : 40%

60%RH 

Please keep away from the places where temperature and humidity can change drastically 
It can cause condensation on the product or deterioration.

 

 

For long-term storage period, we recommened to use within 2 years after receiving the product.  
There is tendency that the leakage current of the aluminium electrolytic capacitors may increase over time when stored without using for long time. 
This phenomenon can be improved by applying voltage to the aluminium electrolytic capacitors in order to reduce the increased of leakage current through 
the self-recovery effect of the electrolyte.  
For reference, before using products that have been stored for a long time, please warm-up first for 30 minutes or more without taking load. 
< Criterion for warm up voltage condition> 
(1)

 

Implementation period : 1 year or above after product delivery 

(2)

 

Electrical continuity condition 
Input voltage : Rating  
Load : 0A 
Ambient temperature : Normal temperature 
Time : 30 minutes or more  

 

Содержание DBM20

Страница 1: ...Ne pas utiliser ce produit dans des conditions anormales comme la pr sence de fum es ou d odeurs inhabituelles ou de bruits suspects etc Merci d arr ter l utilisation imm diatement et d teindre le pro...

Страница 2: ...environnement o des particules conductrices de la poussi re ou des liquides peuvent tre pr sents merci d installer des filtres afin de pr venir toute intrusion de corps trangers l int rieur du produi...

Страница 3: ...Earth Terminal RED LED Discharging Indicator LED will be ON during Buffering mode GREEN LED Charged Indicator LED will be ON during Ready mode DC OK Relay Photo Mosfet Logic low when input voltage is...

Страница 4: ...which is out of specification or reversed may damage the unit 4 2 Nominal Buffer Voltage Range 4 2 1 Fixed mode during buffering mode the nominal buffer voltage level 22 4VDC 4 2 2 VIN 1 mode during b...

Страница 5: ...uffer module provides two option for buffer voltage that is fixed mode and Vin 1 mode Executed using toggle switch to choose between the two options refer to Figure 1 At fixed mode the buffer voltage...

Страница 6: ...C input to the power supply the output from the power supply which is connected to the input output of the buffer module will charge up the internal circuit of the buffer module 2 Once the input outpu...

Страница 7: ...ffering take place buffer signal will change from logic low to high And Ready signal will change from logic high to low 6 During the upstream power supply is still turn ON case and customer system wil...

Страница 8: ...limit of withstand voltage test equipment at 100mA The applied voltage must be gradually increased from zero to testing value and then gradually decreased for shut down When timer is used the buffer m...

Страница 9: ...ng Please refer to section 6 Leave enough space surround the units to ventilate heat efficiently Minimum Installation clearances 40mm on top 20mm at the bottom A 5mm which is recommended on the left a...

Страница 10: ...citor varies depending on the method of mounting the buffer module the load current and the ambient temperature Please refer to the Electronic Capacitor Lifetime Please do not use the product which pa...

Страница 11: ...Ltd Sales Services and R D 1008 Toa Payoh North 06 01 08 07 01 03 Singapore 318996 Telephone 65 62517211 Facsimile 65 62509171 WEBSITE www tdk lambda com sg Note Name plate s contents shown in this in...

Отзывы: