background image

 

Page 

11

 of 

11

 

 

TDK-Lambda 

DBM20 

 

INSTRUCTION MANUAL

 

PA640-04-01B 

EMI (CE) compliance to be confirmed at system level. 
Product is considered as a peripheral accessory to 
Power supply. 
 

10. DBM20 UL508 Listed Condition 
 

 

 

 

 

 

 

 

1)  Wire requirement is rated at minimum 105°C and to use 

copper conductor only. 

2)  For use in a Pollution degree 2 environment only. 
3)  These products are considered for use where maximum 

surrounding air temperature does not exceed 70°C.   
When installing these products please refer to section

 6 

for 

derating. 

4)  Recommended for indoor use only. 

 
11. Warranty period 
 

This product is warranty for a period of 5 years from the date 
of shipment. 
For damage occurring at normal operation within this 
warranty period, repair is free of charge. 
Please read the General Safety Instruction before using the 
products.

 

 

 

 

Product marking: 

 

 

 

TDK-Lambda Singapore Pte. Ltd. 

 (Sales, Services and R&D) 
 1008 Toa Payoh North #06-01/08, #07-01/03 
 Singapore 318996 
 Telephone: +65 62517211 
 Facsimile: +65 62509171 
 WEBSITE: www.tdk-lambda.com.sg 

 
 
 

 
 
 

 
 

Note

 : Name plate's contents shown in this instructimanual 

is for reference only. 

 

 

 

 
 
 
 
 
12. Before concluding that the unit is at fault. 

 

Before concluding that the unit is at fault, make the                 
following checks. 
Check if the rated input voltage is connected. 
Check if the wiring of input and output is correct. 
Check if the wire size is not too thin. 
Check if the buffering current and wattage is not over 
specification. 
Check if the GREEN LED lights up during Ready mode and 
RED LED lights up during Buffer mode.

 

Audible noise can be heard during Dynamic-Load Buffer 
mode operation. 

 

13. Returns 

 
Please contact your local sales office or visit our website to 
arrange return of any faulty product. 

 

 

NOTE : Model name, input voltage range, nominal output 
voltage, maximum output current, country of manufacture 
and safety marking (for only approved products) are shown 
here in accordance with the specifications. 

 

Figure 17 

Содержание DBM20

Страница 1: ...Ne pas utiliser ce produit dans des conditions anormales comme la pr sence de fum es ou d odeurs inhabituelles ou de bruits suspects etc Merci d arr ter l utilisation imm diatement et d teindre le pro...

Страница 2: ...environnement o des particules conductrices de la poussi re ou des liquides peuvent tre pr sents merci d installer des filtres afin de pr venir toute intrusion de corps trangers l int rieur du produi...

Страница 3: ...Earth Terminal RED LED Discharging Indicator LED will be ON during Buffering mode GREEN LED Charged Indicator LED will be ON during Ready mode DC OK Relay Photo Mosfet Logic low when input voltage is...

Страница 4: ...which is out of specification or reversed may damage the unit 4 2 Nominal Buffer Voltage Range 4 2 1 Fixed mode during buffering mode the nominal buffer voltage level 22 4VDC 4 2 2 VIN 1 mode during b...

Страница 5: ...uffer module provides two option for buffer voltage that is fixed mode and Vin 1 mode Executed using toggle switch to choose between the two options refer to Figure 1 At fixed mode the buffer voltage...

Страница 6: ...C input to the power supply the output from the power supply which is connected to the input output of the buffer module will charge up the internal circuit of the buffer module 2 Once the input outpu...

Страница 7: ...ffering take place buffer signal will change from logic low to high And Ready signal will change from logic high to low 6 During the upstream power supply is still turn ON case and customer system wil...

Страница 8: ...limit of withstand voltage test equipment at 100mA The applied voltage must be gradually increased from zero to testing value and then gradually decreased for shut down When timer is used the buffer m...

Страница 9: ...ng Please refer to section 6 Leave enough space surround the units to ventilate heat efficiently Minimum Installation clearances 40mm on top 20mm at the bottom A 5mm which is recommended on the left a...

Страница 10: ...citor varies depending on the method of mounting the buffer module the load current and the ambient temperature Please refer to the Electronic Capacitor Lifetime Please do not use the product which pa...

Страница 11: ...Ltd Sales Services and R D 1008 Toa Payoh North 06 01 08 07 01 03 Singapore 318996 Telephone 65 62517211 Facsimile 65 62509171 WEBSITE www tdk lambda com sg Note Name plate s contents shown in this in...

Отзывы: