TCS ISH3130 Скачать руководство пользователя страница 4

 

07/2012 

TCS TürControlSysteme AG

 

Subject to technical changes. 

E-Mail: [email protected]      www.tcsag.de

 

PI_ISH3130-uk.doc   

1A 

Max. number of ISH3130 in 3-wire operation 

when using power supply 
and control unit 

max. number 

ISH3130 

 

BVS20 or  
NBV1000, 1 line 

20 

BVS100,  
distributed to 3 lines 

80 

VBVS05, 1 line 

90 

BVS20 + NGV1011,  
1 line 

90 

AS  front-door station 
VS  power supply and control unit 
IS  indoor station 
Note: The number of front-door stations which can be 
connected is limited. Details are described in their 
product information!

 

NGV1011,  
3 lines 

270 

 
 

Indication and operating elements 

 

 

handset 
 

  speaking to the door 
  end speaking 

 

 

call OFF-button 

 

shortly press

: ring tone stopper 

 

press for 8 sec

: initiate ring tone selection 

 

 

indication call OFF 
(red) 
 

 

is ON

: call OFF is activated  

 

flashes

: ring tone stopper is deactivated, door release 

automatic or call diversion is activated 

 

flashing OFF

: ring tone stopper is activated, door re-

lease automatic or call diversion is activated 

  error indication: 

 

both LEDs flashing 

  ring tone selection: both LEDs are ON 

 

function key  

  control function 8,  

alternate allocation can be activated: internal call, door 
release automatic, call diversion  

  ring tone selection internal call 

 

 

call indication 
(green) 

 

is ON

: call, speaking is activated  

 

blinks

 3 x: voice channel is busy 

  error indication: 

 

both LEDs flashing 

  ring tone selection: both LEDs are ON 

 

 

light button 

  switch lights 
  ring tone selection floor call (from the flat door) 

 

 

 

door release button 

  open the door 
  trigger light switch function (if light switch function is 

activated in the front-door station) 

  ring tone selection door call of the front-door station 

 

 

volume control for 
voice output and 
ring tone 

adjustable in 8 steps: 

  when voice communication is established 
  when the handset is cradled (no voice communication) 

 

Содержание ISH3130

Страница 1: ...TCS T rControlSysteme AG Subject to technical changes E Mail hotline tcsag de www tcsag de PI_ISH3130 uk doc 1A Product information Door telephone with comfort functions ISH3130...

Страница 2: ...7 Open the device 8 Build in extended functions 8 Connect the lines 9 Connecting lines 9 Wiring example 9 Connection diagram 2 wire technique 10 Connection diagram 3 wire technique 10 Replace an ISH1...

Страница 3: ...tors between heavy and low current lines in shared cable ducts use of standard telecommunication lines e g J Y St Y with 0 8 mm diameter existing lines modernisation with deviating cross sections can...

Страница 4: ...stopper is deactivated door release automatic or call diversion is activated flashing OFF ring tone stopper is activated door re lease automatic or call diversion is activated error indication both L...

Страница 5: ...hite dimensions in mm H 204 x W 100 x D 50 weight 340 g acceptable ambient temperature 5 40 C degree of protection IP30 input current in stand by 2 wire operation I a 1 mA 3 wire operation I a 0 2 mA...

Страница 6: ...2 front door stations via configuration software configo flat door floor door and internal call a parallel call can be activated via Service Device TCSK 01 or configo audio privacy function and automa...

Страница 7: ...mp the lines when snapping on the upper cover Connect the lines according to the labeling a b E P from the button to the top floor push button at a E Wiring example see page 9 Snap on the upper cover...

Страница 8: ...pressure into this opening The upper cover can be removed at the underside 1 Lift the upper cover out of the two upper adjustment increments 2 Installation of extended functions TRE1 radio transmitter...

Страница 9: ...lines Connection lines acceptable cross section diameter 0 08 0 82 mm2 0 32 1 0 mm max number of wires per terminal contact each 2 x 0 8 mm 3 x 0 6 mm Further wires have to be connected with auxiliar...

Страница 10: ...must be replaced with an ISH3130 Commissioning Install the devices of the system voltage free and completely Check the a b and P wire against each other for short circuits Switch on the main voltage...

Страница 11: ...ds The ring tone selected last will be stored 2b select door ring tone of the floor door Press the light switch button until the required ring tone sounds The ring tone selected last will be stored 2c...

Страница 12: ...ase of an internal call x change audio AS limit x block ring tone output x x block ring tone selection x unlimited communication time x reset to factory setting x If the floor door release function in...

Страница 13: ...put it one sided on mass b wire in the power supply optional strand or star formed wiring Table loop resistances cable length in m cable diameter 0 6 mm 0 8 mm loop resistance in 10 1 28 0 71 20 2 55...

Страница 14: ...e a wire or check power supply device is in stand by mode again button stucks press longer than 15 sec remove button at the device or loosen floor push but ton device is in stand by mode again Exchang...

Страница 15: ...off a Not necessary if the bell buttons have not been programmed comp product information of the front door station 1 If there sounds a Progsperr tone instead the front door station is equipped with a...

Страница 16: ...collection point for electronic scrap Dispose the parts of the packaging in collecting tanks for cardboard and paper resp plastics Warranty We offer a simplified processing in case of warranty for el...

Отзывы: