14
07/2012
TCS TürControlSysteme AG
Subject to technical changes.
E-Mail: [email protected] www.tcsag.de
PI_ISH3130-uk.doc
1A
20 Ohm:
max. 160 m distance AS/IS-VS by 0.6 mm diameter
max. 300 m distance AS/IS-VS by 0.8 mm diameter
AS front-door station
VS power supply and control unit
IS
indoor station
FE
extended function
Repair
Error detection and indication
Errors are signalled optically and acoustically: constant flashing and when pressing any
button, an error tone sounds. The optical error indication stays active until the error is cor-
rected.
error causes
display
erro
mode
error tone elimination
a- and P-wire are inter-
changed or short-circuited
both
LEDs
flash
change a- and P-wire or eliminate short-circuit,
device is in stand-by mode again
a-wire: not connected or
not supplied
connect the a-wire or check power supply,
device is in stand-by mode again
button stucks
(press longer than 15 sec)
remove button at the device or loosen floor push but-
ton, device is in stand-by mode again
Exchange an indoor station
– programming bell buttons
Basics
All devices at the TCS:BUS have got an unique serial number.
Programming a bell button means that the serial number of an indoor station is allocat-
ed to the bell button of a front-door station and is stored within the EEPROM of the
front-door station.
Ensure that the new indoor station is connected to the TCS:BUS and the mains voltage
is switched on (the operation LED at the power supply and control unit is ON) and fur-
ther, that the access to the flat is granted during the programming.
This instructions describes the case that a serial number is allocated to the bell button
without setting a programming lock. To neutralise a programming lock you need a Ser-
vice Device TCSK-01or the configuration software configo
™.
a, b short-
circuit here