07/2012
3
TCS TürControlSysteme AG
Subject to technical changes.
E-Mail: [email protected] www.tcsag.de
PI_ISH3130-uk.doc
1A
Scope of delivery
1 x indoor station ISH3130: upper cover, lower cover, handset with handset cord
product information
instruction manual
Safety instructions
!
Attention! Installation, mounting, commissioning and repair of electrical devices have
to be carried out only by qualified electricians. The current standard for the installation
of door communication systems must be observed!
When installing TCS:BUS systems, the general safety regulations for telecommunication
systems according to VDE 0800 must be observed. Inter alia:
separated cabling of heavy and low current lines,
minimum distance of 10 cm for common cabling,
use of separators between heavy and low current lines in shared cable ducts,
use of standard telecommunication lines, e.g. J-Y (St) Y with 0.8 mm diameter,
existing lines (modernisation) with deviating cross sections can be used in compliance
with the loop resistance.
Installation
– protective measures
!
With suitable requirements to protect against lightning, it has to be ensured that a volt-
age of each 32 V DC is not to be exceeded at the connections a, b, P, E.
Intended use
ISH3130 are door telephones for duplex communication with handset for the TCS:BUS.
They are suitable for the operation in TCS audio systems and combined audio/video
systems in the object area.
They are suitable for surface-mount (installation via flush-mounted socket) or desktop
mount with desktop accessory ZIT3030-0010.
Max. number of ISH3130 in 2-wire operation
when using power supply
and control unit
max. number
ISH3130
BVS20 or
NBV1000, 1 line
20
BVS100,
distributed to 3 lines
80
VBVS05, 1 line
30