48
MD-4
path. The optimum balance between Look Ahead and
Attack may be best found as an iterative process, because
less tight peak control in the 5 Band section can put more
processing into the hands of the Limiter. If you use the gain
Defeat function of the 5 Band section, low level transient
handling will be improved by allowing 1 ms of Look Ahead
Delay.
When set to 0.0 ms, the delay through MD4 caused by
additional look ahead structures and up-sampling, amounts
to 38 samples at 44.1 kHz (0.86 ms), 40 samples at
48 kHz (0.83 ms), 93 samples at 88.2 kHz (1.05ms) and 98
samples at 96 kHz (1.02 ms).
Crest
Range: RMS, 24dB, 20dB, 16dB, 14dB, 12dB, 10dB, 6dB
or Peak.
Select compression method between RMS and PEAK
for all bands. The dB-steps between RMS and Peak are
number of dBs needed for a peak-value to override RMS
measurement and can be perceived as a Threshold setting.
Example:
If the Crest parameter is set to 6dB, the Compressor will
respond to RMS values and to peaks 6dB higher than the
current RMS value.
EQ Page
Regardless of sample rate, the Eq in MD4 uses 48 bit, fs/2
analog modeling. You can for instance specify a boost of 3
dB at 28 kHz, even though the machine may be operating
at a sample rate of 44.1 kHz. What this means is that the
part of the 3 dB boost falling inside the current pass-band
(0 to 22.5 kHz) will be applied. Therefore, with the above
example, changing the bandwidth of the 28 kHz boost will
result in a noticeable difference.
Note that MS Configuration provides individual equalization
of the M and the S part of the signal, so you can more
surgically access elements of a complex mix. Because
equalization is performed at 48 bit resolution, MD4 has the
headroom to boost even full scale signals, regardless if
processing is done in the L/R or M/S domain.
EQ
Bypass EQ
EQ Bypass for comparing.
Select A/B
Select which channel to adjust when Mono or MS
Configurations have been chosen. In Stereo Configuration,
the Select key disappears.
Freq
Press and set which frequencies to adjust using the faders.
Gain
Press and set Gain for the selected frequencies.
Type
Select EQ Type between the following types:
- Notch from 0.02 to 1.00 oct
- Parametric from 0.10 to 4 oct
- Shelve 3/6/9/12 dB/oct
- Bessel or Butterworth Lo and Hi Cut
Note: For traditional shelving response, choose Shelve 6
dB/oct.
Lo & Hi
Select switch assigning Lo or Hi end frequency parameters
to faders for adjustments.