vss™ 6.1 - rEvErb
the illustration the grey areas are the directions that are
reproduced at full level.
Front & Surround Level
Range: Off to 0dB
When the Front Restriction parameter is adjusted, the
angle between the frontal and lateral zone is affected.
When the Surround Restriction parameter is adjusted,
the angle between the lateral and dorsal zone is affected.
The level of reflections arriving from the frontal and dorsal
zones are controlled by the level controls Front Level and
Surround Level. If Front Level and Surround Level are set
at 0 dB, there is no reduction of Early Reflection level in
either zone.
Early Start
Range: 0-100%
Adjusting the Start time is an efficient way of getting rid
of the first reflections that normally color the source the
most. By adjusting the Start time, the first reflections are
discarded but the timing of the later reflections remain
unchanged. Therefore this adjustment is typically more
acoustically precise and useful than a normal Predelay
control.
Early Stop
Range: 0-100%
The Early Stop parameter can reduce the later reflections
in the Early Reflections pattern. When using large location
types this can be a useful parameter to smooth the overall
perception of the room.