![TBH BF100R CAB AF5 Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/tbh/bf100r-cab-af5/bf100r-cab-af5_operating-and-maintenance-manual_3791598027.webp)
Safety instructions
27
Do
not
use the device for the extraction of aggressive media or abrasive aluminium dust.
Do not use the device to extract any kind of liquids.
Protect the power cable against heat, moisture, oil and sharp edges.
Observe the supply voltage specified at the notice on the type plate.
Use
genuine spare parts
only.
Use
genuine replacement filters
only.
Do
not
use the device without inserted filter.
Unplug the device before opening it.
The outlet on the back of the device must
not
be covered or blocked by any means.
Make sure the device stands firm and safe.
In case of technical problems, please contact the manufacturer or your specialist retailer!
When extracting carcinogenic substances or welding fumes of materials containing nickel or chrome,
the ventilation requirements specified by the Technical Rules for Hazardous Substances TRGS 560 “Air
recirculation in connection with the treatment of carcinogenic haza
rdous materials” are to be met!
Personal protective equipment (PPE):
Observe local works regulations!
Breathing protection: half mask complying with FFP-3 in line with EN149 (unless specified
otherwise)
Rubber gloves
Safety goggles
Depending on the materi
als’ dangerousness, a protective suit should be worn as well.
1.3
Intended use
These extraction and filter systems are meant to be used for the extraction of dusts and fumes. As
specified at the safety instructions, they must not be used for the extraction of burning or glowing
substances, highly flammable or explosive gases, aggressive media or abrasive aluminium dust and
they must
not
be used for the extraction of any kind of liquids either.