background image

                                                                                                                                 

CS Combi User Manual

 

  TBB Power Co.,Ltd                                                                                                                                        14 / 17 

 

¾

 

Pull

 

through

 

the

 

DC

 

cable

 

through

 

the

 

hole

 

,

 

clamp

 

the

 

cable

 

terminal

 

on

 

cable.

 

¾

 

Connect

 

DC

 

input

 

cable:

 

choose

 

the

 

right

 

cable

 

size

 

and

 

follow

 

polarity

 

guide

 

marked

 

on

 

the

 

panel.

 

Secure

 

the

 

battery

 

cable

 

on

 

DC

 

terminal.

 

¾

 

Pull

 

through

 

the

 

AC

 

input

 

cable

 

through

 

Gland

 

and

 

connect

 

it

 

on

 

AC

 

input

 

block

 

 

¾

 

Pull

 

through

 

the

 

AC

 

output

 

cable

 

through

 

Gland

 

and

 

connect

 

it

 

on

 

AC

 

onput

 

block

   

¾

 

If

 

necessary,

 

pull

 

through

 

the

 

remote

 

controller

 

cable

 

through

 

Gland

 

and

 

connect

 

it

 

on

 

communication

 

port.

   

¾

 

Install

 

the

 

front

 

panel,

 

connect

 

the

 

front

 

panel

 

display

 

cable.

 

tightening

 

of

 

all

 

Gland

 

¾

 

Installed

 

the

 

top

 

panel

 

 

 

 
 

Please

 

double

 

check

 

the

 

AC

 

input

 

and

 

AC

 

output

 

was

 

right

 

after

 

connection.

   

Wrong

 

connection

 

will

 

cause

 

permanent

 

damage

 

of

 

equipment

 

and

 

it

 

is

 

out

 

of

 

warranty.

 

 

 

4

4

.

.

5

5

.

.

3

3

 

 

I

I

n

n

s

s

t

t

a

a

l

l

l

l

 

 

t

t

h

h

e

e

 

 

r

r

e

e

m

m

o

o

t

t

e

e

 

 

c

c

o

o

n

n

t

t

r

r

o

o

l

l

l

l

e

e

r

r

 

 

Please

 

cut

 

the

 

hole

 

according

 

to

 

following

 

size

 

and

 

screw

 

the

 

remote

 

controller

 

securely

 

through

 

four

 

screw

 

at

 

corners.

 

                       

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание CS series

Страница 1: ...CS Combi User Manual TBB Power Co Ltd 1 17 CS series Inverter Charger Combination USER MANUAL Version 2 0 Date Oct 2010...

Страница 2: ...h ISO9001 and can be your reliable power solution provider D Di is sc cl la ai im me er r Unless specially agreed in writing TBB Power Co Ltd Take no warranty as to the accuracy sufficiency of suitabi...

Страница 3: ...ation 1 Please check the input voltage or voltage of battery is same to the nominal input voltage of this inverter 2 Please connect positive terminal of battery to input of the inverter 3 Please conne...

Страница 4: ...designed for indoor use DO NOT block off ventilation otherwise the INVERTER would be overheating 1 2 2 To avoid fire and electric shock make sure all cables selected with right gauge and being connect...

Страница 5: ...quick and right maintenance z Meantime it offer various charging algorithm for multiple battery chemicals including AGM GEL Maintenance Free z Temperature compensation for better charging new model co...

Страница 6: ...ol disconnect 270V 4 THD 5 non liner load High voltage reengage 260V 4 Crest factor 3 1 Nominal input fre 50Hz 60Hz auto detec Efficiency 88 Low frequency trip 47Hz 57Hz Overload 120 15mins High frequ...

Страница 7: ...CS2035M CS3045M CS4065M CS5070M Nomi DC input voltage 24V continuous power W 600 1000 1500 2000 3000 4000 5000 Nominal output voltage 24V Output current A 15 20 30 35 45 65 70 De sulphation 31V for ho...

Страница 8: ...0W 10 1000W 15 1500W 20 2000W 30 3000W 40 4000W 50 5000W X 60 Inverter output power 10 1000W 6000W 25 25A 35 35A 45 45A 65 65A Y 75 Charger capacity 75A L 12VDC M 24VDC Z S Battery bank Voltage 48VDC...

Страница 9: ...ru uc ct tu ur re e a an nd d D Di is sp pl la ay y 3 3 1 1 S St tr ru uc ct tu ur re e There is three size available in CS series please refer to specification for each model Size LxWxH Structure A 4...

Страница 10: ...o op p p pa an ne el l d di is sp pl la ay y 3 3 2 2 2 2 F Fr ro on nt t p pa an ne el l d di is sp pl la ay y Three LED indicating working mode and fault 3 3 2 2 3 3 R Re em mo ot te e C Co on nt tr...

Страница 11: ...G DC cable through hole 3 3 3 3 2 2 C Ce en nt tr ra al l P Pa an ne el l Loose screw and remove the top panel you will see the central panel where all connection block located A Cable to front panel...

Страница 12: ...the equipment in a location of Dry Clean Cool with good ventilation Working temperature 0 40 Storage temperature 40 70 Relative Humidity 0 95 non condensing Cooling forced air Vertical angle No vibrat...

Страница 13: ...tem in case of failure On the AC output side we recommend connecting the output from the inverter to a suitable Residual Current Circuit Breaker and Circuit Breaker On the AC input side the fuse was d...

Страница 14: ...AC onput block If necessary pull through the remote controller cable through Gland and connect it on communication port Install the front panel connect the front panel display cable tightening of all...

Страница 15: ...t voltage of this inverter is same to your battery nominal voltage NEVER try to connect different DC input to inv Inspect the right polarity of DC input otherwise unit can not power ON Inspect AC inpu...

Страница 16: ...y with distilled water Always check the equalization switch is set back to OFF after each time s equalization Battery manufactures recommendations on equalization vary Always follow the battery manufa...

Страница 17: ...battery 31V for 24V battery After some time there is a timer inside the voltage will drop to 11V 22V which indicate this charging finished You can switch off the combi change the setting back to norm...

Отзывы: