background image

                                                                                                                                 

CS Combi User Manual

 

  TBB Power Co.,Ltd                                                                                                                                        8 / 17 

2

2

.

.

3

3

 

 

M

M

o

o

d

d

e

e

l

l

 

 

d

d

e

e

f

f

i

i

n

n

i

i

t

t

i

i

o

o

n

n

 

 

 

 

 

field

 

figure

 

explanation

 

   

CS

 

series

 

name

 

6

 

600W

 

10

 

1000W

 

15

 

1500W

 

20

 

2000W

 

30

 

3000W

 

40

 

4000W

 

50

 

5000W

 

X

 

60

 

Inverter

 

output

 

power:

 

10=1000W

 

6000W

 

25

 

25A

 

35

 

35A

 

45

 

45A

 

65

 

65A

 

Y

 

75

 

 

Charger

 

capacity

 

75A

 

L

 

12VDC

 

M

 

24VDC

 

Z

 

S

 

Battery

 

bank

 

Voltage

   

48VDC

 

 

Example:

 

CS1500M:

 

Pure

 

Sine

 

Wave

 

Inverter

 

24V

 

1500W

 

CS3000L:

 

Pure

 

Sine

 

Wave

 

Inverter

 

12V3000W

 

CS1545L

 

:

 

Inverter

 

Charger

 

Combination

 

12V

 

1500W

 

45A

 

 
 
 

 

 

Содержание CS series

Страница 1: ...CS Combi User Manual TBB Power Co Ltd 1 17 CS series Inverter Charger Combination USER MANUAL Version 2 0 Date Oct 2010...

Страница 2: ...h ISO9001 and can be your reliable power solution provider D Di is sc cl la ai im me er r Unless specially agreed in writing TBB Power Co Ltd Take no warranty as to the accuracy sufficiency of suitabi...

Страница 3: ...ation 1 Please check the input voltage or voltage of battery is same to the nominal input voltage of this inverter 2 Please connect positive terminal of battery to input of the inverter 3 Please conne...

Страница 4: ...designed for indoor use DO NOT block off ventilation otherwise the INVERTER would be overheating 1 2 2 To avoid fire and electric shock make sure all cables selected with right gauge and being connect...

Страница 5: ...quick and right maintenance z Meantime it offer various charging algorithm for multiple battery chemicals including AGM GEL Maintenance Free z Temperature compensation for better charging new model co...

Страница 6: ...ol disconnect 270V 4 THD 5 non liner load High voltage reengage 260V 4 Crest factor 3 1 Nominal input fre 50Hz 60Hz auto detec Efficiency 88 Low frequency trip 47Hz 57Hz Overload 120 15mins High frequ...

Страница 7: ...CS2035M CS3045M CS4065M CS5070M Nomi DC input voltage 24V continuous power W 600 1000 1500 2000 3000 4000 5000 Nominal output voltage 24V Output current A 15 20 30 35 45 65 70 De sulphation 31V for ho...

Страница 8: ...0W 10 1000W 15 1500W 20 2000W 30 3000W 40 4000W 50 5000W X 60 Inverter output power 10 1000W 6000W 25 25A 35 35A 45 45A 65 65A Y 75 Charger capacity 75A L 12VDC M 24VDC Z S Battery bank Voltage 48VDC...

Страница 9: ...ru uc ct tu ur re e a an nd d D Di is sp pl la ay y 3 3 1 1 S St tr ru uc ct tu ur re e There is three size available in CS series please refer to specification for each model Size LxWxH Structure A 4...

Страница 10: ...o op p p pa an ne el l d di is sp pl la ay y 3 3 2 2 2 2 F Fr ro on nt t p pa an ne el l d di is sp pl la ay y Three LED indicating working mode and fault 3 3 2 2 3 3 R Re em mo ot te e C Co on nt tr...

Страница 11: ...G DC cable through hole 3 3 3 3 2 2 C Ce en nt tr ra al l P Pa an ne el l Loose screw and remove the top panel you will see the central panel where all connection block located A Cable to front panel...

Страница 12: ...the equipment in a location of Dry Clean Cool with good ventilation Working temperature 0 40 Storage temperature 40 70 Relative Humidity 0 95 non condensing Cooling forced air Vertical angle No vibrat...

Страница 13: ...tem in case of failure On the AC output side we recommend connecting the output from the inverter to a suitable Residual Current Circuit Breaker and Circuit Breaker On the AC input side the fuse was d...

Страница 14: ...AC onput block If necessary pull through the remote controller cable through Gland and connect it on communication port Install the front panel connect the front panel display cable tightening of all...

Страница 15: ...t voltage of this inverter is same to your battery nominal voltage NEVER try to connect different DC input to inv Inspect the right polarity of DC input otherwise unit can not power ON Inspect AC inpu...

Страница 16: ...y with distilled water Always check the equalization switch is set back to OFF after each time s equalization Battery manufactures recommendations on equalization vary Always follow the battery manufa...

Страница 17: ...battery 31V for 24V battery After some time there is a timer inside the voltage will drop to 11V 22V which indicate this charging finished You can switch off the combi change the setting back to norm...

Отзывы: