CS Combi User Manual
TBB Power Co.,Ltd 16 / 17
5
5
.
.
5
5
P
P
e
e
r
r
f
f
o
o
r
r
m
m
i
i
n
n
g
g
D
D
e
e
s
s
u
u
l
l
p
p
h
h
a
a
t
t
i
i
o
o
n
n
C
C
h
h
a
a
r
r
g
g
i
i
n
n
g
g
It
is
strongly
recommended
to
read
this
section
carefully
before
you
set
the
de
‐
sulphation
charging
and
DO
NOT
leave
battery
unattended
while
performing
de
‐
sulphation.
About Desulphation
Frequency:
Maximum
once
a
month,
you
may
wish
to
equalize
your
flooded
batteries
by
using
the
battery
charger
equalization
mode.
Important:
Equalization
can
damage
your
batteries
if
it
is
not
performed
properly.
Never
equalize
a
battery
more
than
twice
a
month.
Always
check
battery
fluid
before
and
after
equalization.
Fill
batteries
only
with
distilled
water.
Always
check
the
equalization
switch
is
set
back
to
OFF
after
each
time’s
equalization.
Battery
manufactures’
recommendations
on
equalization
vary.
Always
follow
the
battery
manufacturer’s
instructions
so
batteries
are
properly
equalized.
As
a
guide,
a
heavily
used
battery
may
require
equalization
once
a
month
while
a
battery
in
light
duty
service,
only
needs
equalizing
once
every
2
to
4
months.
Battery
type
Only
perform
equalization
to
flooded
lead
‐
acid
batteries.
Do
not
equalize
Gel,
AGM
batteries.
Performing an Equalization
During
equalization,
the
battery
generates
potentially
flammable
gases.
Follow
all
the
battery
safety
precautions
listed
in
this
guide.
Ventilate
the
area
around
the
battery
thoroughly
and
ensure
that
there
are
no
sources
of
flame
or
sparks
in
the
vicinity
When
battery
temperature
reach
above
50C,
please
stop
charging.