MPPT charge controller User Manual
2
and heat dissipation.
If the ambient temperature and
ventilation is normal, please
contact your dealer.
09 PSU_LV
Auxiliary power of the
charger is too low.
Please contact your dealer.
10 PSU_LV_HD
11 Sam_HD_Fault
The Charger has
sampling failure.
12 EEPROM_Fail
Abnormal storage of
the charger.
13 EPO(Remote OFF)
2P phoenix terminal
didn’t insert into the
EPO of the charger.
Insert the 2P phoenix terminal
into the EPO of the charger. And
charger will return to normal
operation after the failure
disappears.
If no, please contact your dealer.
Warning
01 U_BAT_OV
Battery voltage is too
high.
Check whether the battery settings
of the charger are consistent with
the battery configuration.
02 U_BAT_LV
Battery voltage is too
low.
Please check the battery voltage.
Wait the charger charging until the
battery voltage normally.
03 Cur_Limit
Charging current over
range.
Check whether the maximum
charging current is over range.
Check whether the charger
model setting is correct.
If the settings are correct, please
contact your dealer.
04 BAT_UnConnect
Battery connection
failure.
Please check the battery circuit
breaker.
06 T_BAT_OT
Battery temperature
is too high
Check whether ambient
temperature is in range.
Check that the charger
installation environment is well
ventilated.
If the ambient temperature is too
high or is not ventilated well,
please improve its ventilation
and heat dissipation.
08
TypeSet_Mismatch
_Err
The charger model
setting in not correct.
Check whether the charger
model setting is correct.
And change the model settings.
14 NTC_Board_Fault
The NTC of the
charger is fault.
Please contact your dealer.