20
Controls and Systems
Models 150, 152, 162, 168
(Old Style Only)
On the front of the watt control there are three colored
jumper wires (white, blue, and yellow). The proper
range selection is determined by running the freezer to
determine the beater motor amperage when product
reaches the desired viscosity and cutting the jumper
wire(s) indicated on the range selection chart.
With no jumper wires cut, use the following procedure
to determine the proper range selection.
Step 1
Locate the L1 power path passing through the control
to the beater motor (socket connection #5 and #6).
Install an ampmeter on the L1 power path to monitor
the amperage of the beater motor.
Step 2
Turn the viscosity adjustment potentiometer clockwise
to the coldest setting.
Step 3
During the freezing process, draw samples and
inspect the product until the desired appearance is
achieved, note the beater motor amperage. Slowly
turn the viscosity adjustment potentiometer
counterclockwise to “WARMER” until the refrigeration
system cycles off.
Note: If the refrigeration system cycles off before the
desired product viscosity is achieved, the watt control
range selection must be adjusted. Check the range
selection chart and advance to the next higher range
by cutting the prescribed jumper wire(s). Repeat Step
3 until the correct adjustment is set.
Step 4
Draw several samples to verify that the off-cycle
setting and the product appearance remains
consistent.
Note: On old style controls, if the wrong wire is cut
when setting the amperage range selection, simply
solder the wire back together.
Содержание Taylormate 150
Страница 2: ......
Страница 18: ...14 Controls and Systems Models 150 152 162 168 130521 Refrigeration Schematic Figure 5 ...
Страница 33: ...29 Models 150 152 162 168 Parts Section 4 Parts S Parts Warranty S Exploded Views S Parts List ...
Страница 35: ...31 Models 150 152 162 168 Parts Notes ...
Страница 36: ...32 Parts Models 150 152 162 168 160210 Model 150 Exploded View Figure 9 ...
Страница 40: ...36 Parts Models 150 152 162 168 160210 Model 152 Exploded View Figure 12 ...
Страница 42: ...38 Parts Models 150 152 162 168 Model 162 Exploded View Figure 13 ...
Страница 46: ...42 Parts Models 150 152 162 168 Model 168 Exploded View Figure 16 ...
Страница 72: ...Model 150 152 050416 12 11 15 Taylor Company 2015 Carrier Commercial Refrigeration Inc c ...
Страница 73: ...Model 150 152 050416 27 11 15 Taylor Company 2015 Carrier Commercial Refrigeration Inc c ...
Страница 74: ...Model 150 152 050416 40 11 15 Taylor Company 2015 Carrier Commercial Refrigeration Inc c ...