10
Introduction
Models 150, 152, 162, 168
Electrical Connections
In the United States, this equipment is
intended to be installed in accordance with the
National Electrical Code (NEC), ANSI/NFPA 70-1987.
The purpose of the NEC code is the practical
safeguarding of persons and property from hazards
arising from the use of electricity. This code contains
provisions considered necessary for safety.
In all other areas of the world, equipment should be
installed in accordance with the existing local codes.
Please contact your local authorities.
Each unit requires one power supply for each data
label on the unit. Check the data label(s) on the freezer
for branch circuit overcurrent protection or fuse, circuit
ampacity, and other electrical specifications. Refer to
the wiring diagram provided inside of the electrical box
for proper power connections.
FOLLOW YOUR LOCAL ELECTRICAL CODES!
CAUTION: THIS EQUIPMENT MUST BE
PROPERLY GROUNDED! FAILURE TO DO SO
CAN RESULT IN SEVERE PERSONAL INJURY
FROM ELECTRICAL SHOCK!
Note:
This unit is provided with an equipotential
grounding lug that is to be properly attached to either
the rear of the frame or the under side of the base pan
near the entry hole for incoming power, by the
authorized installer. The installation location is marked
by the equipotential bonding symbol (5021 of IEC
60417-1) on both the removable panel and the
equipment’s frame, as well as on the diagram.
S
DO NOT
operate the freezer with larger
fuses than specified on the data label.
S
Stationary appliances which are not
equipped with a power cord and a plug or
another device to disconnect the appliance
from the power source must have an all-pole
disconnecting device with a contact gap of
at least 3 mm installed in the external
installation.
S
Appliances that are permanently connected
to fixed wiring and for which leakage
currents may exceed 10 mA, particularly
when disconnected, not used for long
periods, or during initial installation, shall
have protective devices such as a GFI to
protect against the leakage of current,
installed by authorized personnel to the local
codes.
S
Supply cords used with this unit shall be
oil-resistant, sheathed flexible cable, not
lighter than ordinary polychloroprene or
other equivalent synthetic
elastomer-sheathed cord (Code designation
60245 IEC 57) installed with the proper cord
anchorage to relieve conductors from strain,
including twisting, at the terminals and
protect the insulation of the conductors from
abrasion.
Failure to follow these instructions may result in
electrocution or damage to the machine.
Beater Rotation
Beater rotation must be
clockwise
as viewed
looking into the freezing cylinder.
The following repairs must be performed by an
authorized Taylor Service Technician.
Disconnect all power to the unit.
Failure to
follow this instruction may result in electrocution.
To correct rotation on a three-phase unit, interchange
any two incoming power supply lines at the freezer
main terminal block only.
To correct rotation on a single-phase unit, change the
leads inside the beater motor by following the diagram
printed on the motor label.
Содержание Taylormate 150
Страница 2: ......
Страница 18: ...14 Controls and Systems Models 150 152 162 168 130521 Refrigeration Schematic Figure 5 ...
Страница 33: ...29 Models 150 152 162 168 Parts Section 4 Parts S Parts Warranty S Exploded Views S Parts List ...
Страница 35: ...31 Models 150 152 162 168 Parts Notes ...
Страница 36: ...32 Parts Models 150 152 162 168 160210 Model 150 Exploded View Figure 9 ...
Страница 40: ...36 Parts Models 150 152 162 168 160210 Model 152 Exploded View Figure 12 ...
Страница 42: ...38 Parts Models 150 152 162 168 Model 162 Exploded View Figure 13 ...
Страница 46: ...42 Parts Models 150 152 162 168 Model 168 Exploded View Figure 16 ...
Страница 72: ...Model 150 152 050416 12 11 15 Taylor Company 2015 Carrier Commercial Refrigeration Inc c ...
Страница 73: ...Model 150 152 050416 27 11 15 Taylor Company 2015 Carrier Commercial Refrigeration Inc c ...
Страница 74: ...Model 150 152 050416 40 11 15 Taylor Company 2015 Carrier Commercial Refrigeration Inc c ...