16
SERVICE FUNCTIONS MENU STRUCTURE
•
Press the Menu button to find the desired menu then press the OK button to select the menu.
•
Use the Up
and Down
arrow buttons to find the desired function.
•
Press the OK button to select the desired function.
•
Menu button exits function at any time and returns to Main menu.
Note:
A Service Password is available. Use the Service Password if the manager’s password has been misplaced.
The Service Password operates in the Service menu only and will erase the manager’s password and restore to default
(no password). The Service Password sequence is:
Small Basket, Up arrow, Down arrow, Large Basket, Medium Basket (twice), then OK button.
Function Name
Description
Error Counts
Displays the number of occurrences of each error. Press OK button to enter function.
Display shows Error and Number of Occurrences (Counts).
•
Up arrow shows next error.
•
Down arrow shows previous error.
•
Menu button closes function and returns to Service menu.
Clear Functions
Allows for clearing the Error Log, Held Errors, and to reset Dispenser Parameters. Display
shows a blinking function (Error Log, Held Errors and Parameter [Parameter refers to factory
defaults]).
•
Up arrow will advance to next function.
•
Down arrow to previous function.
•
OK button selects function.
Display will now blink Keep.
Up and Down arrows will change display between Keep and Reset (Keep retains current
settings, Reset clears Error Log, and Held Errors, and resets Parameters [Factory
Defaults]).
Pressing OK selects Keep or Reset, closes function, and returns to Service.
Note:
Scale must be calibrated if Parameters (factory defaults) reset.
Press the Menu button at any time to abort function and return to the Service menu.
Adjust Temp.
(adjust temperature probe)
Note:
See procedure on page 29.
Caution:
Read procedure on page 29 before continuing.
Displays the current temperature probe reading in tenths of a degree e.g. -1.5°F.
Allows the cabinet temperature probe to be corrected.
•
Up arrow will increase temperature in 0.1° increments.
•
Down arrow will decrease the temperature in 0.1° increments.
OK button will save the setting and return to Service menu.
Scale Readout
Displays the live units used to calculate weight,
the live calibrated weight in pounds or grams,
and the tare setting. OK button closes function
and returns to the Service menu.
Scale:
Live units / Tare
Live Calibrated weight / Tare Setting