19
Test Outputs
Turns on and off outputs for diagnostic
purposes.
Display shows a flashing Refrig:
•
Up and Down arrow buttons change the output selection (Refrig, Drum, or Accum).
•
OK button selects the output.
Display will show selected output and a flashing Out:
•
Up arrow turns on the output, * appears next to “Out”.
•
Down arrow turns off the output, removes *.
Menu button exits the function and returns to Service menu
Note:
The refrigeration system has a 2-minute short cycle delay. The refrigeration
system will turn on when the “Refrigeration timeout” has reached zero (0) and the
refrigeration (“Refrig”) bypass function is set to ON
.
Set Password
Allows a password to be set to access both Configuration and Service functions. (Default is
no password.) (See page 28.)
Press OK button to enter function. Display reads “Set Password”
and “--------“.
Use basket size buttons and Up and Down arrows to enter up to an eight-digit password.
When finished, press the OK button. (Any sequence of the basket size buttons and Up
and Down arrow buttons can be used to create a password.) Display reads “Repeat
Password” and “--------“. Repeat the password sequence, then press OK to save the
password and exit to the Service menu. (See note below for Service Password.)
Main Screen
Press OK to exit Service menu and return to the Main screen.
Function Name
Description
Output selection Refrig timeout
Out:_