
17
Refrig Monitor
Displays the present state of the refrigeration
system.
Refrigeration Cycle:
•
“Wait” = In short cycle delay or in Bypass mode.
•
“Cool” = Initial cooling cycle.
•
“On” = Normal refrigeration cycle, compressor on.
•
“Off” = Normal refrigeration cycle, compressor off.
Timeout – Number of seconds remaining in refrigeration short cycle delay.
•
Door: Door Switch status. * indicates door switch on, door closed.
•
Out: Compressor output status. * indicates compressor output is on. Compressor
should be running.
•
Back: Refrigeration Feedback Relay status. Used to diagnose refrigeration system.
•
OK button closes function and returns to the Service menu.
Weighing Monitor
Displays the present state of the
weighing system.
Weighing cycle
•
Idle - Waiting for a basket size selection.
•
Check - Checking Tare weight
•
Dispens - In dispense cycle.
•
Pulsing - Nearing target weight
•
Drop - Dispensing product into basket
•
Empty - Dispense cycle has completed, target weight not met.
•
Disable - No load selection has been made.
•
“Live weight” is the actual calibrated weight on the accumulator doors.
•
Out: Drum motor output (* is present when output is on, numbers just to the right indicate
current is present.)
•
“Load size” is the current basket load size selection.
•
OK button closes function and returns to the Service menu.
Accum Monitor
Displays the present state of the
accumulator doors.
Accum. door position:
•
Open - Doors.
•
Close - In dispense cycle.
•
Out: Accumulator door motor output, * indicates on. Number to right indicates current.
•
“Accum door state” is the current door state, “Ajar” or “Closed.”
•
Home: * Indicates home position has been reached during cycle.
•
OK button closes function and returns to Service menu.
Function Name
Description
Refrig. Cycle
Door:_
Timeout
Out:_
Back:_
Weighing cycle Live weight
Out:_
Load size
Accum. door position
Out:_
Accum door state
Home:_