18
Sensor Monitor
Displays the present state of the
Basket Sensor.
“Sensor:_” * indicates sensor is reading a
basket present.
“Basket State” indicates present basket cycle.
•
“None” - No basket is present.
•
“Basket” - Basket is present waiting to be filled.
•
“Filled” - Basket is present and has been filled.
“Weigh cycle” indicates position in the weighing cycle
•
Idle - Waiting for a basket size selection.
•
Check - Checking tare weight.
•
Dispens - In dispense cycle.
•
Pulsing - Nearing target weight
•
Drop - Dispensing product into basket.
•
Empty - Dispense cycle has completed, target weight not met.
•
Disable - No load selection has been made.
OK button closes function and returns to the Service menu.
Fry Monitor
Used to set the Low Fry Sensor
Alarm level. The Low Fry Alarm will turn on
after the Low Fry Sensor stops sensing fries
and a set amount of fries has been dispensed.
If no fries are sensed at start up, the display will
read “No Fry Sensor.” Once fries are sensed, the display will read “Low Fry Sensor_.”
The “_” indicates the Low Fry Sensor is active.
Sensor level set point
Shows the amount of weight which must dispense, once the sensor stops sensing fries
and before the alarm turns on.
Up and Down arrow buttons change the Sensor Level setting.
Current level
Shows the weight remaining before the alarm turns on. If the sensor is indicating fries
present, the Sensor Level set point and the Current level will be the same.
Menu button exits the function and returns to the Service menu.
Bypass Functions
Note:
Volatile setting. (will reset
each time power is cycled)
Used to bypass certain dispenser systems to allow for diagnosing problems or to operate if a
system has failed (sensor). The systems are the refrigeration system, the weighing cycle,
and the basket sensor.
Display will read a flashing Refrig.
•
Use the Up and Down arrow buttons to change from Refrig,
Weigh or Sensor.
•
OK button selects system to be bypassed.
Display will read a flashing ON.
•
Up and Down arrow buttons change between ON and OFF, then press the OK
button. (Select OFF to bypass the selected system.)
Display returns to Service menu.
Note:
Press the Menu button at any time to abort function and return to the Service menu.
Function Name
Description
Basket
Sensor_
Basket State Weigh cycle
Low Fry Sensor_
Sensor level set point Current level