29
Small
and the current target weight for the small setting
displayed. Press the Up and Down arrow buttons to
change between
Small, Medium,
and
Large
. Press the
OK button to select the desired load size. The current
target weight will begin to flash.
To change the target weight for the currently selected
basket load size, press the Up arrow
to increase the
target weight or the Down arrow
to decrease the
target weight in 0.05 lb. (25 g) increments. Use the OK
button to save the new setting. The display will return to a
flashing load size (Small, Medium, or Large).
Repeat until all adjustments have been made. Press the
OK button to store all new settings. Use the Menu button
to return to the menu selections (User, Configuration, and
Service) and close the function.
Use the
Main Screen
function in the menus to return to
the Main screen.
Adjusting the Basket Guide Bar
The basket tray can be adjusted to allow for the use of
larger width baskets. The basket tray has predrilled holes
to allow for the repositioning of the basket guide bars.
Remove the two screws holding the basket guide bar.
Reposition the basket guide bar to the second set of
holes as indicated in the picture below. Install and tighten
the mounting screws.
Note:
Basket trays are shown in the standard guide
position.
Figure-18
Temperature Probe Calibration
The RAM R200 Frozen Food Dispenser uses a single
temperature probe mounted to the wall of the cabinet
compartment in the upper right. It is the temperature
displayed on the main screen panel and also used to
control the refrigeration system.
The temperature control is factory set. Unless the
controller or the temperature probe are replaced, it will
not be necessary to change these values. In addition,
raising or lowering the target temperature can
compensate for small discrepancies between the probe
temperature and actual temperature. However,
differences of greater than 2ºF (1.1ºC) should be
corrected. The method for adjusting the temperature
probe is simple, but requires an accurate thermometer
(preferably certified) to measure the probe’s deviation
from the actual temperature:
Place the thermometer into the freezer compartment as
close to the cabinet temperature probe as practical. The
machine should be operating at or near normal operating
temperature. If the thermometer has a sensing probe,
make certain that it is not touching any metal in the
compartment. Otherwise it may give a false reading.
Wait 5 minutes with the Dispenser operating normally
and the door closed.
Check the thermometer reading and compare it with the
temperature displayed on the operator panel. The best
time to check is just after the compressor shuts off.
If the difference between the display and the
thermometer is greater than 2ºF (-16.7ºC), an adjustment
should be made.
Note:
Calibration of the temperature probe is performed
from the Service Functions menu using the operator
panel on the front of the Dispenser, and may require a
manager’s password to access the menu.
To access the Service menu on the operator panel, press
the Menu arrow button until the display shows
Service
Menu
with
“--------”
below
Service menu
is displayed.
If a password is required, the display will show
" ----- "
below
Service Menu
after pressing the OK button. Enter
the manager’s password then press the OK button.
Use the Up or Down buttons to scroll through the
functions to
Adjust
Temp
., then press the OK Button to
select function.
The display will change to
Adjust Temp.
with the current
temperature probe reading displayed in the lower right of
the display.
1
Basket Tray
2
Basket Guide Bar Mounting Holes for Large Basket
2
1